FILE NO. SVM-09036
-
23
-
7-
3
-4. Heating operation *Heat pump model only
([MODE] button on the remote control is set
to the heating operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display lamp are controlled as shown in
Fig. 7-3-6.
Fig. 7-
3
-
6
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-3-7. When
[FAN] button is set to LOW, LOW
+
, MED, MED
+
or
HIGH, the motor operates with a constant air flow.
7-
3
-3. Dry operation
([MODE] button on the remote control is set
to the dry operation.)
(1) The compressor, 4-way valve,
(Heat pump model
only) outdoor fan and operation display lamp are
controlled as shown in
Fig. 7-3-4.
Fig. 7-
3
-
4
(2) The microprocessor turns the compressor on and
off at the regular intervals (4 to 6 minutes). While
the compressor is turning off, the indoor fan motor
operates in the SUPER LOW position.
The pattern of operation depending on the relation
between room temperature and preset
temperatures is shown in Fig. 7-3-5.
Fig. 7-
3
-
5
(3) [FAN] button on the remote control is set to AUTO
only.
(4) The ECO, COMFORT SLEEP, QUIET and
Preset
temp.
+3
+2
+1
0
OFF
ON
OFF
4-way valve
Outdoor fan
OPERATION
Compressor
ON:6min. OFF:4min.
ON:5min. OFF:5min.
OFF
ON:6min. OFF:4min.
ON:5min. OFF:5min.
display lamp
(Room temp.)
(Preset temp.)
Room temp.
Preset temp.+1
Preset temp.
Compressor
Outdoor fan
Indoor fan
L. *S.L.
S.L.
L.
L.
S.L.
L.
ON
ON
ON
ON
OFF
OFF
OFF
*Super Low
ON
OFF
ON
OFF
ON
ON
4-way valve
Outdoor fan
Compressor
Preset
temp.
OPERATION display lamp
0
0.5
(Room temp.)
(Preset temp.)
[FAN AUTO]
-0.5
-1
-1.5
-2
*1
*2
-5.0
-5.5
0
Preset
temp.
M+
H
L
°
C
(Room temp.)
−
(Preset temp.)
° C
° C
*2 : Fan speed = (M +
−
L) x 2/4 + L
*1 : Fan speed = (M +
−
L) x 1/4 + L
*3 : Fan speed = (M +
−
L) x 3/4 + L
(Calculated with Linear approximation from M+ and L+)
Fig. 7-3-7
Hi POWER operations can not be set.