– 13 –
FILE NO. SVM-09036
5-1. RAS-18SKP-ES / RAS-18SA-ES
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard 0.94 10.6 High 27/19 35/24
Cooling High temperature 1.09 15.0 High 32/23 43/26
Low temperature 0.75
4.3
Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure P
(MPaG)
Cross flow fan
Compressor
Propeller fan
Outdoor unit
PA200X2CS-4KU1
O.D.:12.7 mm
O.D.:6.35 mm
Packed valve
(
∅
12.7)
Packed valve
(
∅
6.35)
T
P
Refrigerant
R410A 1.65 kg
0.39 m
(Connecting pipe)
∅
12.7
0.49 m
(Connecting pipe)
∅
6.35
Mark ( ) means check points of Gas Leak
Capillary tube
∅
2.0x
11
00
s
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Heat exchanger
Heat exchanger
5. REFRIGERATION CYCLE DIAGRAM