FILE NO. SVM-09036
-
21
-
Table 7-2-2
L
L+
M
M+
H
Low
Table (7-2-1) Cooling
(L + M) / 2
Table (7-2-2) Heating
Med
(M + H) / 2
High
Indication Fan speed
L
L+
M
M+
H
Low
(L + M) / 2
Med
(M + H) / 2
High
Indication
Fan speed
7-
2
-1.
according to the setup temperature, room temperature,
Louver contr
2) When setting the fan speed to AUTO on the remote
ol
controller, revolution of the fan motor is controlled
(1)
to the fan speed level show in Table 7-2-3
V
and heat exchanger temperature.
er
Table 7-2-3 Indoor fan and air flow rate
tical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button
is stored in the microcomputer, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [SWING] button is pressed, it stops
swinging.
7-
2
-2.
Indoor Fan Control
The operation controls the fan speed at indoor unit
side. The indoor fan (cross flow fan) is operated by
the phase control induction motor. The fan rotates in 5
stages in MANUAL mode, and in 5 stages in AUTO
mode, respectively. (Table 7-2-3)
1) When setting the fan speed to L, L+,M, M+ or H
on the remote controller, the operation is performed
with the constant speed shown in Table 7-2-1 and
7-
2
. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
a DC motor for an indoor fan. The DC motor drive
circuit is mounted in the indoor unit. And electrical
parts which operate the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
The air conditioner is mainly controlled by the indoor
unit controller. The controller operates the indoor fan
motor based upon commands transmitted by the
remote control and transfers the operation commands
to the outdoor unit.
The outdoor unit receives operation commands
from the indoor unit, and operates the outdoor
fan motor and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation
commands from the remote control and executes
them.
•
Temperature measurement at the air inlet of the
indoor heat exchanger by the indoor
temperature sensor
•
Temperature measurement of the indoor heat
exchanger by the heat exchanger sensor
•
Louver motor control
•
Indoor fan motor operation control
•
LED display control
•
Transferring of operation commands to the
outdoor unit
•
Receiving of information of the operation status
and judging of the information or indication of
error
(2) Role of outdoor unit controller
The outdoor unit controller receives the operation
commands from the indoor controller and
executes them.
•
Compressor operation
control
•
Operation control of
outdoor fan motor
•
Turning off the compressor and outdoor fan
when the outdoor unit receives the shutdown
command
•
Defrost control in heating operation
(Temperature measurement by the Indoor heat
exchanger, control the four-way valve and
outdoor fan motor control)
Operations according
to the commands
from the indoor unit
H
M+
M
L+
L
L-
UL
SL
H
M+
M
L+
L
L-
M+
M
L+
L
L-
UL
SL
1050
980
900
850
750
650
550
950
880
800
800
650
550
450
1125
1050
1000
950
850
700
600
1025
950
900
850
750
600
500
UH
H
M+
M
L+
L
L-
UL
SL
H
M+
M
L+
L
L-
Dry
M+
M
L+
L
L-
UL
SL
UH
H
M+
M
L+
L
L-
UL
SL
1000
1000
940
870
850
850
750
640
550
900
900
840
770
750
750
650
540
450
1050
1050
1050
950
950
950
850
700
600
950
950
950
850
850
850
750
600
500
1200
Air flow volume (m
3
/h)
1100
Model
rpm
Air flow volume (m
3
/h)
Heat
RAS-24SKP-ES
rpm
RAS-18SKHP-ES
Fan only
Cooling
Dry
RAS-18SKP-ES
rpm
Cooling
Fan only
RAS-24SKHP-ES
Model
FAN TAP
FAN TAP
rpm
Air flow volume (m
3
/h)
Air flow volume (m
3
/h)
UH
1100
1000
1100
1000
1200
1100
OPERATION
MODE
OPERATION
MODE