4-3. Outdoor Unit (RAS-24SA-ES)
–
11
–
FILE NO. SVM-09036
No.
Parts name
Type
Specifications
1 Fan motor (for indoor)
ICF-340-30-2B
DC 340V, 30W
2 Thermo sensor (TA-sensor) ——— 10 k
Ω
at 25
°
C
3
Switching Transformer (T01)
SWT-77 DC 7V, 12V
4 Microcontroller
TMP87CM40ANG-6P68
5
Heat exchanger sensor
——— 10 k
Ω
at 25
°
C
(TC-sensor)
6 Line filter (L01)
LC*SS11V-R06270 27mH, 600mA
7 Diode (DB01)
D
3SBA60 4
A, 600 V
8 Capacitor (C
03
)
EKMH451VSN121MQ35S 120
µ
F, 450 V
9 Fuse (F01)
BET 6.3A
6.3 A, 250 V
1
0
Varistor (
R09, R10
)
SR561K14DL
560 V
11 Resistor (R01) RF-5TK1R8 1.8
Ω
, 5W
12 Louver motor MP24Z3T Output (Rated) 2 W, 6 poles, 1-2 phase,
DC 12 V
No.
Parts name
Type
Specifications
Output (Rated) 2
0
00W, 2poles, 1 phase, 220
−
240V, 50Hz
1
Compressor
PA2
70X3CS-4MU2
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
1.
37
2.
55
Output (Rated) 42W, 4poles, 1 phase, 220
−
240V, 50Hz
2
Fan motor (for outdoor)
FG-240-42A
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
128
126
3
Running capacitor
DS451355NPQB AC 450V, 3.5
µ
F
(for fan motor)
4
Running capacitor
B32332I5606J063 AC 450V, 60
µ
F
(for compressor)
5
Magnetic contactor CLK-35J
220
−
240V, 50Hz
4-4. Indoor Unit (RAS-18SKHP-ES, RAS-24SKHP-ES)