6F3B0250
Basic Hardware and Function
101
6. Programming Information
Device/
register
Name
Function
SW07
Clock/calendar (Year)
Lower 2 digits of the calendar year
(98, 99, 00, 01, ... )
SW08
Clock/calendar (Month)
Month (01, 02, ... 12)
They are stored in
SW09
Clock/calendar (Day)
Day (01, 02, ... 31)
the lower 8 bits by
SW10
Clock/calendar (Hour)
Hour (00, 01, ... 59)
BCD code
SW11
Clock/calendar (Minute)
Minute (00, 01, ... 59)
(T1S only)
SW12
Clock/calendar (Second)
Second (00, 01, ... 59)
SW13
Clock/calendar (Week)
Day of the week
(Sun = 00, Mon = 01, ... Sat = 06)
SW14
-
Reserved
SW15
Peripheral support priority
Bit 8 (S158) is used to select peripheral support priority
(T1S only)
SW16
Mode of special input
functions
Used to select the special input functions
SW17
Input filter constant
Used to set the input filter constant
SW18
Preset values for high
Used to set the preset values for high speed counters
SW19
speed counter
SW20
SW21
SW22
Count values for high
Present count values of the high speed counters are
SW23
speed counter
stored
SW24
High speed counter control
flags
Control flags for the high speed counters
SW25
-
Reserve
SW26
Mode of special output
functions
Used to select the special output functions
SW27
Special output control flags Control flags for the pulse/PWM output
SW28
Special output frequency
setting
Output frequency setting for the pulse/PWM output
SW29
PWM output duty setting
Pulse duty setting for the PWM output
SW30
Analog setting value 1
Input value of the analog setting adjuster V0
SW31
Analog setting value 2
Input value of the analog setting adjuster V1
SW32
AUX LED control
Bit 0 (S320) is used to control AUX LED
(T1-40/T1-40S only)
SW33
-
Reserved
SW34
TL-F10 send data
TOSLINE-F10 transmission data (send to master)
SW35
TL-F10 receive data
TOSLINE-F10 transmission data (receive from master)
SW36
PRG port station address
Used to set the programmer port station address
(1 to 32) (T1S only)
SW37
PRG port parity
Used to set the programmer port parity (0=none, 1=odd)
(T1S only)
SW38
PRG port response delay
Used to set the programmer port response delay time
(0 to 30: 0 to 300ms)
NOTE
(1) For details of SW16 though SW31, refer to section 8.
(2) For details of SW34 and SW35, refer to the Expansion I/O manual.
(3) For details of SW36 through SW38, refer to the Communication function
manual.