e-STUDIO2500c/3500c/3510c OUTLINE OF THE MACHINE
May 2006 © TOSHIBA TEC
2 - 24
7) Thermistors, thermopiles, and thermostats
8) Transformer
DH3
DRM-DH-L
Drum damp heater (Left)
Preventing condensation of the drum
Fig. 2-14
42-110
DH4
DRM-DH-R
Drum damp heater (Right)
Preventing condensation of the drum
Fig. 2-14
36-26
Symbol
Name
Function
Remarks
P-I
THM1
THMS-DRM-Y
Drum thermistor-Y
Detecting the surface temperature of
the drum for Y
Fig. 2-7
38-33
THM2
THMS-DRM-K
Drum thermistor-K
Detecting the surface temperature of
the drum for K
Fig. 2-7
38-33
THM3
THMS-FBLT-F
Fuser belt front thermistor
Detecting the surface temperature of
the front end of the fuser belt
Fig. 2-9
43-21
THM4
THMS-PR-C
Pressure roller center thermistor
Detecting the surface temperature of
the center of the pressure roller
Fig. 2-9
44-14
THM5
THMS-PR-R
Pressure roller rear thermistor
Detecting the surface temperature of
the rear end of the pressure roller
Fig. 2-9
44-14
THMP1 THMP-FBLT-C
Fuser belt center thermopile
Detecting the surface temperature of
the center of the fuser belt
Fig. 2-9
46-4
THMP2 THMP-FBLT-R
Fuser belt rear thermopile
Detecting the surface temperature of
the rear end of the fuser belt
Fig. 2-9
46-4
THMO1 THERMO-FBLT-C
Fuser belt center thermostat
Preventing overheating of the center
portion of the fuser belt
Fig. 2-9
43-20
THMO2 THERMO-FBLT-S
Fuser belt rear thermostat
Preventing overheating of the rear por-
tion of the fuser belt
Fig. 2-9
43-19
THMO3 THERMO-PR
Pressure roller thermostat
Preventing overheating of the pressure
roller in the fuser unit
Fig. 2-9
44-13
THMO4 THERMO-SCN-DH
Scanner damp heater thermostat
Controlling the temperature of the
scanner damp heater
Fig. 2-14
12-22
THMO5 THERMO-DRM-DH-L
Drum damp heater thermostat (Left)
Controlling the temperature of the drum
damp heater
Fig. 2-14
42-34
THMO6 THERMO-DRM-DH-R
Drum damp heater thermostat (Right)
Controlling the temperature of the drum
damp heater
Fig. 2-14
36-27
Symbol
Name
Function
Remarks
P-I
HVT
PS-HVT
High-voltage transformer
Generating high-voltage and supplying
it to the following sections
•
Main charger needle electrode
•
Main charger grid
•
Developer bias
•
Transfer bias
Fig. 2-13
8-8
Symbol
Name
Function
Remarks
P-I
Summary of Contents for e-STUDIO2500c
Page 130: ...e STUDIO2500c 3500c 3510c CONTROL PANEL May 2006 TOSHIBA TEC 5 18 ...
Page 158: ...e STUDIO2500c 3500c 3510c SCANNER May 2006 TOSHIBA TEC 6 28 ...
Page 168: ...e STUDIO2500c 3500c 3510c IMAGE PROCESSING May 2006 TOSHIBA TEC 7 10 ...
Page 188: ...e STUDIO2500c 3500c 3510c DRIVE SYSTEM May 2006 TOSHIBA TEC 9 2 ...
Page 232: ...e STUDIO2500c 3500c 3510c PAPER FEEDING SYSTEM May 2006 TOSHIBA TEC 10 44 ...
Page 256: ...e STUDIO2500c 3500c 3510c PROCESS UNIT RELATED SECTION May 2006 TOSHIBA TEC 11 24 ...
Page 288: ...e STUDIO2500c 3500c 3510c DEVELOPER UNIT May 2006 TOSHIBA TEC 12 32 ...
Page 401: ......