FUSER UNIT
13 - 11
7. Abnormality detection by the thermistors
The table below shows the judging conditions of abnormal temperatures of the fuser roller and the
pressure roller, and their checking timing.
Checking
timing
Conditio
n
Temperature judged
Error
code
Counter
(08-400)
Error
judging
timing
Center
thermist
or
Rear
thermist
or
Front
thermist
or
Pressure
roller
thermist
or
Power ON
1
240°C or
above
-
-
-
C449
9
Power ON
-
250°C or
above
-
-
-
-
270°C or
above
-
-
-
-
250°C or
above
C468
8
2
40°C or
below
150°C or
above
-
-
C412
2
150°C or
above
40°C or
below
-
-
Detecting
40°C
1
240°C or
above
-
-
-
C449
19
On usual
-
250°C or
above
-
-
-
-
270°C or
above
-
-
-
-
250°C or
above
C468
18
2
40°C or
below
-
-
-
C412
(C411)
2
(1)
Fixed time
-
40°C or
below
-
-
Detecting
100°C
1
240°C or
above
-
-
-
C449
21
On usual
-
250°C or
above
-
-
-
-
270°C or
above
-
-
-
-
250°C or
above
C468
18
2
100°C or
below
-
-
-
C446
(C443)
3
(6)
Fixed time
-
100°C or
below
-
-
When pre-
running end
temperature /
ready
temperature
is detected
1
240°C or
above
-
-
-
C449
22
On usual
-
250°C or
above
-
-
-
-
270°C or