e-STUDIO555/655/755/855
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
DRUM/CLEANER UNIT
10 - 14
(3) Disconnect 2 connectors, remove 3 screws
and take off the motor and solenoid with the
bracket.
Fig. 10-27
(4) Remove 2 screws and take off the cleaning
brush drive motor.
(5) Remove 2 screws and take off the drum
separation finger solenoid.
Note:
Pay attention to the size (length) of the
screws. If incorrect ones are used, the motor
could be damaged.
Fig. 10-28
Bracket
Screw
Screw
Drum separation finger solenoid
Cleaning brush
drive motor