5.2.3
Menu display
The menu display of the converter LCD display section has a hierarchical structure as shown in
Table 5.2.3.
Note: Occasionally using some abbreviated terms as well, actual LCD displays differ from Table
5.2.3. For details, refer to Section 5.2.4. The symbols in parentheses in Table 5.2.3
correspond to those displayed on the upper left corner of their respective LCD screens.
Table 5.2.3 Menu Display (1)
Menu 1
Menu 2
Menu 3
Menu 4
Density multiplier (C)
Upper density measurement range (UR)
Lower density measurement range (LR)
Density line slope (a)
Density intercept (b)
Density test output(ot)
Delayed time in external synchronized operation
(dt)
Zero-point phase
θ
1
(zp)
Zero-point fluid temperature T
0
(zT)
RF correction factor (cG)
Zero-point RF data (zG)
Moving average times (ma)
Permissible width of change-rate limit (dx)
Read
parameters
Limit times of change-rate limit (HL)
Measured value Phase
θ
2
(p), fluid temperature (T),
ambient temperature (A), density (X)
Operation status (ST)
Microwave signal level (SL)
Micro wave factor (F)
RF data(G)
+5V power supply voltage(J)
Reference phase error (pd)
Monitorin
g
menu
Self-diagnosis
data
Memory check (Mc)