Ambient environment condition:
Temperature: 0 to 50
°
C (Option: Detector
−
20 to 50
°
C)
Humidity:
5 to 90%RH (No condensation)
Structure:
Detector Immersion-proof type (IP67: Immersion-proof type or equivalent)
Converter Waterproof type (IP65: Waterproof type or equivalent)
Note: Outdoor installation is possible. If there is a possibility of direct sunlight, however,
provide a sunshade to the converter to avoid direct sunlight.
Vibration:
(1) Applying vibration of a resonant frequency in 5 to 150 Hz range in x, y and z
directions for 30 minutes each totaling 90 minutes, and no deterioration of
performance nor damage shall be found.
However, acceleration is as follows:
•
Detector: 25m/s2
•
Converter: 4.9m/s2
(2) Applying vibration of 5 to 150 to 5 Hz with the acceleration shown in (1) above for
3 minutes and this is repeated 10 times for each direction of vibration totaling 90
minutes, and no deterioration of performance nor damage shall be found.
Altitude
: Up to 2000m
Mass:
Refer to the Attached Figure 1, “Dimensions” in “Appendix.”
Microwave transmission power:
Approx. 10W
11.2 Detector Specifications
Meter size:
50mm, 80mm, 100mm, 150mm, 200mm, 250mm, 300mm
Flange standard and maximum operating pressure
Flange standard
Maximum operating pressure
JIS 10K(JIS B 2238 10K) or equivalent
1MPa
ANSI150
1MPa
DIN10 & BS 10
1MPa
DIN 16
1.6MPa
Fluid temperature:
0 to 100
°
C (Not freezing)
Fluid conductivity:
Meter size
Fluid conductivity
50 mm
20 mS/cm or less
80 mm
16 mS/cm or less
100 mm
15 mS/cm or less
150 mm
10 mS/cm or less
200 mm
8 mS/cm or less
250 mm
8 mS/cm or less
300 mm
6 mS/cm or less
Note: Precautions about measuring fluids
When measuring density in liquids containing conductive particles such as the carbon
particles of activated carbon or metal powder, density measurement may be affected by