5.2.13 Phase angle rotation correction display and operating procedures
Move the cursor to "8" with [
→
] key, and press [SET] key
to select [8:ANGLE ROTATION]
5:SET PARAMETERS
6:ZERO CALIBRATION
7:SPAN CALIBRATION
8:ANGLE ROTATION
UH:UPPER ANGLE
DATA : 260
[SET] CHANGE
[ESC] RETURN
SH:LOWER ANGLE
DATA :100
[SET] CHANGE
[ESC] RETURN
UH:UPPER ANGLE
RANGE :240-360
°
DATA : 260
[SET] SET,[ESC] CANCEL
[SET](Set)
[SET](Fix)
[ESC](Cancel)
SH:LOWER ANGLE
RANGE :0-120
DATA : 100
[SET] SET,[ESC] CANCEL
[SET](Set)
[SET](Fix)
[ESC](Cancel)
N:ROTATION
DATA
:
0
[SET] CHANGE
[ESC] RETURN
N:ROTATION
RANGE :
−
10 - 10
DATA : 00
[SET] SET,[ESC] CANCEL
[SET](Set)
[SET](Fix)
[ESC](Cancel)
UH:UPPER ANGLE
DATA :260
[SET] CHANGE
[ESC] RETURN
Before shipping, this value is set to 260 degrees. Changing
the setting may result in damaging the otherwise normal
operation. Therefore, normally, do not change the setting.
Before shipping, this value is set to 100 degrees. Changing
the setting may result in damaging the otherwise normal
operation. Therefore, normally, do not change the setting.
Normally, the angle rotation N is automatically computed;
therefore, it is unnecessary to change the setting through
manual input. However, there are some cases of high density
measurements which require settings through manual input.
[ESC]
(Previous
Menu)
[ESC]
(Previous
Menu)
[ESC]
(Previous
Menu)
[ESC]
(Previous
Menu)
[DN]
(Pre. menu)
[UP]
(Next menu)
[DN]
(Pre. menu)
[UP]
(Next menu)
[DN]
(Pre. menu)
[UP]
(Next menu)