Problem
Possible Cause
Corrective Action
1. The key was turned to the S
TART
position before the glow-plug light
turned off.
1. Turn the key to the R
UN
position and
allow the glow-plug light to turn off
before starting the engine.
2. The engine temperature is low.
2. Check the thermostat.
3. The glow plugs are inoperative.
3. Check the fuse, glow plugs, and wiring.
4. The injection-pump timing is incorrect.
4. Contact your Authorized Service
Dealer.
5. The injection nozzles are damaged.
5. Contact your Authorized Service
Dealer.
Exhaust produces excessive white smoke.
6. There is low compression.
6. Contact your Authorized Service
Dealer.
1. The parking brake is engaged.
1. Disengage the parking brake.
2. The hydraulic-fluid level is low.
2. Add hydraulic fluid to the reservoir.
3. The hydraulic system is damaged.
3. Contact your Authorized Service
Dealer.
4. The tow valves are open.
4. Close the tow valves.
5. The flow-divider valve lever is in 9
o'clock position.
5. Move the lever to the 12 o'clock to 10
o'clock position.
6. A traction pump drive coupler is loose
or broken.
6. Contact your Authorized Service
Dealer.
7. Pump and/or wheel motor is damaged.
7. Contact your Authorized Service
Dealer.
8. The control valve is damaged.
8. Contact your Authorized Service
Dealer.
The machine does not drive.
9. The relief valve is damaged.
9. Contact your Authorized Service
Dealer.