Removing the Rate Control
Manifold Valve
1.
Remove clamps and gaskets that secure the
manifold for the rate control valve (
).
Note:
Retain the clamp(s) and gasket(s) for
installation in
Installing the Rate Control Manifold
.
g028536
Figure 88
1.
Flange (pressure filter
head)
4.
Clamp
2.
Manifold (rate control
valve)
5.
Gasket
3.
Flange (agitation valve)
6.
3-pin connector (valve
actuator—rate control
valve)
2.
Remove the retainer that secure the outlet fitting
to the manifold for the rate control valve (
g028537
Figure 89
1.
Flanged-head bolt
4.
Retainer
2.
Valve mount
5.
Socket (outlet fitting)
3.
Flanged locknut
6.
Manifold-valve assembly
3.
Remove the 2 flanged-head bolts and 2 flanged
locknuts that secure the rate control valve to
the valve mount and remove the valve manifold
from the machine (
).
Note:
If necessary, loosen the mounting
hardware for the pressure filter head to ease
removal of the rate control valve..
Removing the Agitation Manifold
Valve
1.
Remove clamps and gaskets that secure the
manifold for the agitation valve (
) to
the agitation bypass valve, rate control valve,
master boom valve, and adapter fitting (agitation
throttle valve).
Note:
Retain the clamp(s) and gasket(s) for
installation in
Installing the Agitation Manifold
.