Installing the Rate Control
Manifold Valve
1.
Align a gasket between the flanges of the rate
control valve manifold and the pressure filter
head (A of
Note:
If needed, loosen the mounting hardware
for the pressure filter head as needed to provide
clearance.
g028538
Figure 101
1.
Locknut
5.
Gasket
9.
Manifold valve
assembly
2.
Valve mount
6.
Clamp
10.
Socket (outlet
fitting)
3.
Flange
(agitation
valve)
7.
Flange
(pressure filter
head)
11.
Retainer
4.
Flanged-head
bolt
8.
Flange (rate
control valve)
2.
Assemble the rate control valve manifold,
gasket, and pressure filter head with a clamp
and tighten by hand (A of
3.
Align a gasket between the flanges of the rate
control valve and the agitation valve manifold
(A of
).
4.
Assemble the rate control valve manifold,
gasket, and agitation valve manifold with a
clamp and tighten by hand (A of
).
5.
Assemble the rate control valve to the valve
mount with the 2 flanged-head bolts and 2
flanged locknuts (A of
) that you
removed in step
of
Manifold Valve (page 67)
and torque the nut and
bolt to 1017 to 1243 N-cm (90 to 110 in-lb).
6.
Assemble the outlet fitting onto the lower endcap
fitting of the manifold valve (B of
).
7.
Secure the endcap fitting to the outlet fitting by
inserting a retainer into the socket of the outlet
fitting (B of
).
8.
If you loosened the mounting hardware for the
pressure filter head, tighten the nut and bolt to
1978 to 2542 N-cm (175 to 225 in-lb).
Installing the Agitation Manifold
Valve
1.
Align the flange of the agitation valve manifold,
a gasket, and the flange of the agitation bypass
valve (A of
).
Note:
If needed, loosen the mounting hardware
for the master boom valve as needed to provide
clearance.
72
Summary of Contents for Multi Pro WM 41240
Page 79: ...Schematics g255886 Flow Diagram Sprayer System DWG 125 0699 Rev B 79...
Page 80: ...Notes...
Page 81: ...Notes...
Page 82: ...Notes...