9
Installing the Sprayer Fuse
Block
Parts needed for this procedure:
1
Fuse decal (127–3966)
Procedure
1.
Squeeze the sides of the battery cover to release
the tabs from the slots in the battery base, and
remove the battery cover from the battery base
(
).
g028456
Figure 22
1.
Slot (battery base)
3.
Tab (battery cover)
2.
Cover (negative battery
terminal)
4.
Terminal (positive battery
cable)
2.
Slide the cover back and remove the negative
battery terminal from the battery (
).
3.
Remove the positive battery terminal from the
battery (
).
4.
Locate the uninsulated receptacle terminal at the
end of the open, yellow power wire of the fuse
block for the machine and the insulated blade
terminal at the end of the yellow, optional-power
wire of the fuse block of the sprayer wiring
(
).
g028444
Figure 23
1.
Back of the machine
4.
Uninsulated receptacle
terminal (yellow power
wire—sprayer fuse block)
2.
Fuse block (sprayer
wiring)
5.
Fuse block (machine
wiring)
3.
Insulated blade
terminal(yellow,
optional-power
wire—machine fuse block)
5.
Connect the uninsulated receptacle terminal of
the fuse block for the machine to the insulated
blade terminal of the fuse block of the sprayer
(
).
6.
Align the T-fittings on the of the fuse block of
the sprayer to the T-slots of the fuse block for
the machine and slide the sprayer fuse block
into the slots until the fuse block is fully seated
(
).