• Failure to comply with the safety information and instructions given in this

manual or with the accident prevention regulations and general safety
regulations relevant to the field of application shall exempt the manufacturer or
its representative from all liability and shall render any damage claims null and
void.

2.1

Intended use

The  product  is  designed  exclusively  for  opening  and  closing  spring-balanced  or
weight-balanced  garage  doors.  It  may  not  be  used  for  garage  doors  without
spring-balancing or weight-balancing mechanisms.
Never make any modifications or changes to the product that have not been ex-
pressly approved by the manufacturer.
The product is suitable for domestic use only.

2.2

Foreseeable misuse

Any use other than described in chapter Intended use is regarded as reasonably
foreseeable misuse. This includes but is not limited to:

• using the product as a drive for sliding door constructions
• using the product for garage doors without spring-balancing or weight-

balancing mechanisms

Any damage or injury as a result of reasonably foreseeable misuse or of not fol-
lowing the assembly and operating instructions will render the manufacturer's liab-
ility null and void.

2.3

Personnel qualifications

Only personnel who are familiar with this manual and the dangers associated with
handling this product may use this product. The individual activities require differ-
ent personnel qualifications listed in the following table.

Activities

Operating
personnel

Skilled workers

a

 with

relevant training, e.g.
industrial mechanic

Skilled
electrician

b

Installation, assembly, commissioning

X

X

Electrical installation

X

Operation

X

Cleaning

X

Maintenance

X

X

X

Work on the electrical system
(troubleshooting, repair & deinstallation)

X

Work on the mechanical system
(troubleshooting & repair)

X

Disposal

X

X

X

Summary of Contents for B-1200

Page 1: ...B 1200 WN 930002 63 6 50 03 2020...

Page 2: ...ce document que ce soit sous forme lectronique ou m canique y compris la photocopie et l enregistrement ind pendamment de l utilisation recherch e est interdite sans l autorisation crite pr alable de...

Page 3: ...4 Installation und Montage 10 4 1 Sicherheitshinweise f r die Installation und Montage 10 4 2 Antriebe und Zubeh r 10 4 3 Lieferumfang 11 4 4 Vorbereitung der Montage 12 4 5 Montage des Garagentorantr...

Page 4: ...tor von Hand ffnen und schlie en 29 5 4 Garagentor ffnen und schlie en weitere Betriebsarten 30 6 Fehlersuche 30 7 Diagnoseanzeige 31 7 1 Werkseinstellungen wiederherstellen 32 7 2 Zyklenz hler 32 8 I...

Page 5: ...n Ihnen zum besseren Verst ndnis von Sachverhalten und Handlungsabl ufen Die Darstellun gen in den Abbildungen sind beispielhaft und k nnen geringf gig vom tats chli chen Aussehen Ihres Produktes abwe...

Page 6: ...en ganzen K rper hin 1 4 Hinweis und Infosymbol HINWEIS HINWEIS weist auf wichtige Informationen z B auf Sachsch den aber nicht auf Gef hrdungen hin Info Hinweise mit diesem Symbol helfen Ihnen Ihre T...

Page 7: ...altung der angegebenen Sicherheitshinweise und Anweisungen in diesem Handbuch sowie der f r den Einsatzbereich geltenden Unfallverh tungsvorschriften und allgemeinen Sicherheitsbestimmungen sind jegli...

Page 8: ...an der Elektrik St rungsbeseitigung Reparatur Deinstallation X Arbeiten an der Mechanik St rungsbeseitigung Reparatur X Entsorgung X X X a Als Fachkraft gilt wer aufgrund seiner fachlichen Ausbildung...

Page 9: ...ein 1 Freischalten 2 Gegen Wiedereinschalten sichern 3 Spannungsfreiheit feststellen Arbeiten an der Elektrik d rfen nur von Elektrofachkr ften oder un terwiesenen Personen unter Leitung und Aufsicht...

Page 10: ...ranschlusskonsole 3 Laufschiene Modellbeispiel Antriebsseite 12 Schubstange 4 Laufschlitten 13 Mittenabh ngung 7 Laufschienenverbinder Modellbeispiel 16a Deckenbefestigung Antriebskopf 8 Laufschiene M...

Page 11: ...elastbarkeit 1000 N Schutzklasse IP20 nur f r trockene R ume Anschlusswerte 230 V 50Hz Lautst rke 70 dBA Leistungsaufnahme Hersteller Novoferm tormatic GmbH Standby 4 W Eisenh ttenweg 6 Max Betrieb 41...

Page 12: ...der Antrieb und f hrt in die Gegenrichtung um das Hindernis freizugeben Das Tor kann durch er neute Impulsgabe wieder geschlossen werden 4 Installation und Montage 4 1 Sicherheitshinweise f r die Ins...

Page 13: ...17 15 19 11 13 10 Abb 4 Lieferumfang 1 Antriebskopf mit LED Modul 11 Toranschlusskonsole 2 Antriebsritzel 12 Schubstange 3 Laufschiene Modellbeispiel Antriebsseite 13 Mittenabh ngung 4 Laufschlitten...

Page 14: ...alliert sein Das mitgelieferte Netzanschlusskabel ist ca 1 2 m lang berpr fen Sie die Stabilit t des Tors ziehen Sie Schrauben und Muttern am Tor nach berpr fen Sie das Tor auf einwandfreien Lauf schm...

Page 15: ...iebskopf 1 Montieren Sie die Deckenbefestigungen 16 anschlie end an die Decke 6 Montieren Sie die Schubstange 12 zwischen Laufschlitten 4 und Toranschlusskonsole 11 7 Zur Programmierung ffnen Sie die...

Page 16: ...versorgung indem Sie den Netzstecker ziehen Schlie en Sie keine spannungsf hrenden Leitungen an Es d rfen nur potenzialfreie Taster und Relaisausg nge angeschlo en wer den Schlie en Sie nach dem Ansch...

Page 17: ...LS 2 1 2 1 2 I H G F E 8k2 REL LS 4 1 2 3 4 5 LS 4 1 2 I H G F E 8k2 I H G F E 24V 8k2 6 7 8 9 10 K 230V P J I H G F E P I H G F E REL 24V E43U 8k2 11 12 13 K L L N 1 N N N M M M N N N M M M K L M N O...

Page 18: ...ster anschlie en 8 K Anschluss f r externe schutzisolierte Beleuchtung oder Signallampe Schutzklasse II max 500 W Zubeh r 9 F I Spannungsversorgung 24 V DC max 100 mA permanent 10 P Anschluss f r Mobi...

Page 19: ...er externen Antenne muss die Abschirmung auf die daneben liegende Klemme F gelegt werden 4 8 Antriebskopf programmieren In diesem Abschnitt wird die Basisprogrammierung des Antriebs im Rahmen der Inst...

Page 20: ...kabel mit einer Netzsteckdose Die Punktanzeige leuchtet auf 4 8 2 Men 1 Startfunktion f r den Handsender D A1 Abb 9 Startfunktion f r den Handsender programmieren 1 Dr cken Sie die Programmiertaste PR...

Page 21: ...HINWEIS Maximal k nnen 30 Codes eingelernt werden Beispielsweise 15x Start 15x Licht F r die Programmierung der L ftungsstellung und Teil ffnung sie he Men 9 4 8 4 L schen aller am Antrieb programmier...

Page 22: ...r ckt bis das Garagentor die gew nschte End position AUF erreicht hat Dr cken Sie ggf die ZU Taste C um die Position zu korrigieren 4 Wenn sich das Garagentor in der gew nschten Endposition AUF befind...

Page 23: ...ahrt beginnt immer aus der Endposition ZU HINWEIS Wir empfehlen vor der Kraftlernfahrt den entsprechenden Tor typ in Men 8 auszuw hlen B Abb 14 Kraftlernfahrt 1 Dr cken Sie die AUF Taste B oder benutz...

Page 24: ...ffnungen von gr er 50 mm oder Trittfl chen ist die Kraftbegrenzungseinrichtung in ff nungsrichtung zu berpr fen Bei zus tzlicher Belastung des Tores mit 20 kg Masse muss der Antrieb stoppen HINWEIS Fa...

Page 25: ...gen HINWEIS Wir empfehlen vor der Kraftlernfahrt den entsprechenden Tor typ in Men 8 auszuw hlen 1 W hlen Sie Men punkt 5 Nach ca 2 Sekunden blinkt die Anzeige und der eingestellte Wert der Kraftbegre...

Page 26: ...r AUF B und ZU C Tasten an Wert Lichtzeit Vorwarnzeit Blinkfunktion 0 60 s 0 s nein 1 120 s 0 s nein 2 240 s 0 s nein 3 0 s 0 s ja 4 0 s 3 s nein 5 0 s 0 s nein 6 0 s 3 s ja 7 90 s 3 s nein 8 90 s 3 s...

Page 27: ...ntsprechenden Tortypen aus 2 Passen Sie die Einstellung ggf mithilfe der AUF B und ZU C Tasten an Men wert Tortyp 0 Doppelfl geltor 1 Nichtausschwingendes Tor Canopy 2 Schwingtor Kipptor normal 3 Schw...

Page 28: ...on AUF Eine weitere Impulsgabe w hrend der Auffahrt ist ohne Einfluss und das Tor f hrt weiter auf Nach Impulsgabe in AUF Position f hrt das Tor zu Bei Impulsgabe w hrend der Zufahrt stoppt das Tor un...

Page 29: ...0 s 3 60 s 4 90 s 5 120 s 6 150 s 7 180 s 8 210 s 9 240 s 3 Dr cken Sie die Programmiertaste PROG Taste D Der Wert H wird angezeigt 4 9 7 Men H Einstellungen STOPP A 1 W hlen Sie Men punkt H Nach ca 2...

Page 30: ...anwendbaren Sicherheitsvorschriften vertraut sein Halten Sie die f r den Einsatzbereich geltenden rtlichen Unfallverh tungsvorschriften und allgemeinen Sicherheitsbestimmungen ein Bewahren Sie Handse...

Page 31: ...liert bewegen Das Garagentor ist m glicherweise nicht mehr korrekt ausbalanciert oder die Federn sind besch digt oder besitzen nicht mehr die notwendige Spannkraft Setzen Sie sich mit dem zust ndigen...

Page 32: ...em Schlie en ffnet sich das Tor wieder einen Spalt breit Tor blockiert kurz vor Zuposition Endposition nicht richtig eingestellt Hindernis entfernen Endposition ZU neu einstellen lassen Antrieb f hrt...

Page 33: ...ut ein Garagentor ffnet oder schlie t nicht Unterbrechung auf STOPP A oder Ausl sung externe Sicherheitseinrichtung z B Schlupft r Garagentor schlie t nicht Unterbrechung auf STOPP B oder Ausl sung ex...

Page 34: ...ungen und Klemmverbindungen des Schlupft rkontaktes 7 1 Werkseinstellungen wiederherstellen 1 Dr cken Sie gleichzeitig die Tasten AUF B und ZU C C B Abb 17 Werkseinstellungen 2 Halten Sie beide Tasten...

Page 35: ...en Antriebstyp Fabrikationsdatum Hersteller Betriebsart Tordaten Typ Konstruktionsjahr Seriennummer Gewicht Torblatt Abmessungen Installation Erstinbetriebnahme Firma Installationsbetrieb Name Install...

Page 36: ...ktions und Wartungst tigkeiten sind im beiliegenden Inspektions und Pr fprotokoll zu dokumentieren Der Betreiber Eigner ist verpflichtet das Inspektions und Pr fprotokoll zusammen mit der Dokumentatio...

Page 37: ...Gewicht 2 1 Federn Zustand Sitz Einstellung 2 1 1 Federb nder Zustand 2 1 2 Federbruchsicherung Zustand Typenschild 2 1 3 Sicherheitseinrichtungen Federverbindung Zustand Sitz 2 2 Drahtseile Zustand...

Page 38: ...g Funktion Zustand 5 4 Lichtschranken Funktion Zustand 5 5 Schlie kantensicherung Funktion Zustand 6 0 Dokumentation Betreiber Eigner 6 1 Typenschild CE Kennzeichen vollst ndig lesbar 6 2 Konformit ts...

Page 39: ...sch getestet WARNUNG Quetschgefahr am Tor Bei einer zu hohen Einstellung der Kraftbegrenzung besteht Verlet zungsgefahr f r Personen Im Auslieferungszustand ist der eingestellte Wert beim ffnen 6 und...

Page 40: ...unalverwaltung Durch die getrennte Sammlung von Elektro und Elektronik Altger ten sollen die Wiederverwendung die stoffliche Verwertung bzw andere Formen der Verwertung von Altger ten er m glicht sowi...

Page 41: ...ndigen einzelstaatlichen Stellen ber unsere Dokumentationsabteilung zu bermitteln Produktmodell Produkt B 1200 Produkttyp Garagenantrieb Baujahr ab 2019 Einschl gige EG EU Richtlinien 2014 30 EU 2011...

Page 42: ...Safety information for installation and assembly 48 4 2 Drive and accessories 48 4 3 Scope of delivery 49 4 4 Preparing for installation 50 4 5 Mounting the garage door drive 51 4 5 1 Disengage the ca...

Page 43: ...door 67 5 4 Opening or closing the garage door other operation modes 67 6 Troubleshooting 68 7 Diagnostic display 68 7 1 Restoring the factory settings 70 7 2 Cycle counter 70 8 Inspection and test l...

Page 44: ...y from your product s actual appearance 1 2 Pictograms and signal words Important information in this manual is marked with the following pictograms DANGER DANGER indicates a hazardous situation which...

Page 45: ...h the product Read and comply with all safety information and instructions Only use the product for the intended use as mentioned in this manual Keep all safety information and instructions for future...

Page 46: ...reseeable misuse This includes but is not limited to using the product as a drive for sliding door constructions using the product for garage doors without spring balancing or weight balancing mechani...

Page 47: ...duct is safe to operate when used as intended Nevertheless residual risks remain DANGER Hazardous voltage Fatal electric shock when touching live parts Observe the follow ing safety rules when working...

Page 48: ...LED module 11 Door connector attachment 3 Rail model example drive side 12 Linking bar 4 Carriage 13 Central support 7 Rail connector model example 16a Ceiling mountings on drive head 8 Rail model exa...

Page 49: ...x load capacity 1000 N Protection class IP20 for dry rooms only Power supply 230 V 50Hz Sound level 70 dBA Power input Manufacturer Novoferm tormatic GmbH Standby 4 W Eisenh ttenweg 6 Max operation 41...

Page 50: ...s an obstruction during opening the drive stops and moves back to release the obstruction The door can be closed again by pulsing 4 Installation and assembly 4 1 Safety information for installation an...

Page 51: ...5 2 9 3 7 8 16 14 17 15 19 11 13 10 Fig 4 Scope of delivery 1 Drive head including LED module 11 Door connector attachment 2 Pinion 12 Linking bar 3 Rail model example drive side 13 Central support 4...

Page 52: ...pply The supplied power cable is approx 1 2 m long Check the door for stability and re tighten the screws and nuts on the door Check the door for correct movement and lubricate the shafts and bearings...

Page 53: ...nd to the drive head 1 Then mount the ceiling mountings 16 to the ceiling 6 Connect the linking bar 12 between the carriage 4 and the garage door connector attachment 11 7 For programming open the cov...

Page 54: ...l out the main plug from the mains socket before you open the cover of the drive head Do not connect any live leads Only connect potential free buttons and potential free relay outputs After connectin...

Page 55: ...2 1 2 1 2 I H G F E 8k2 REL LS 4 1 2 3 4 5 LS 4 1 2 I H G F E 8k2 I H G F E 24V 8k2 6 7 8 9 10 K 230V P J I H G F E P I H G F E REL 24V E43U 8k2 11 12 13 K L L N 1 N N N M M M N N N M M M K L M N O 14...

Page 56: ...or signal lamp protection class II max 500 W accessory 9 F I Power supply 24 V DC max 100 mA permanent 10 P Connection for Mobility Module accessory 11 L Connection for staircase control device potent...

Page 57: ...rnal antenna the shield must be placed on the adjacent terminal F 4 8 Programming the drive head This section describes the normal programming of the drive head during installa tion Programming the co...

Page 58: ...ocket The point display lights up 4 8 2 Menu 1 Start function for the hand transmitter D A1 Fig 9 Programming the start function for the hand transmitter 1 Briefly press the programming button PROG bu...

Page 59: ...transmitter see Step 1 NOTICE Up to 30 codes can be learned Example 15x start and 15x light For programming the ventilation position and partial opening see menu 9 4 8 4 Deleting all hand transmitters...

Page 60: ...s 3 Keep the OPEN button pressed until the garage door is at the desired end position OPEN If needed press the CLOSE button C to adjust the position 4 Once the garage door is at the desired end positi...

Page 61: ...must disappear The force learning cycle always starts from the end position CLOSE NOTICE We recommend selecting the according door type in menu 8 before carrying out the force learning cycle B Fig 14...

Page 62: ...oor reaches the obstruction the garage door must stop and then move back to the end position OPEN 3 If the door can lift persons e g openings greater than 50 mm or treads the force limiting unit must...

Page 63: ...e factory setting is 6 for opening and 4 for closing The force on the main closure side must not exceed 400 N 750 ms NOTICE We recommend selecting the according door type in menu 8 before carrying out...

Page 64: ...and CLOSE C but tons Value Light time Warning time Flashing function 0 60 s 0 s no 1 120 s 0 s no 2 240 s 0 s no 3 0 s 0 s yes 4 0 s 3 s no 5 0 s 0 s no 6 0 s 3 s yes 7 90 s 3 s no 8 90 s 3 s yes 9 0...

Page 65: ...d adjust the setting with the aid of the OPEN B and CLOSE C but tons Menu value Door type 0 Double swing gate 1 Non swinging door Canopy 2 Swing door tilting door normal 3 Swing door tilting door sens...

Page 66: ...e during upward motion has no effect and the door continues to open After generating a pulse in OPEN position the door closes When generating a pulse during closing the door stops and opens again 6 Au...

Page 67: ...lect menu item H After approximately 2 seconds the display flashes and shows the set value of the operating mode The factory setting is 0 2 If desired adjust the setting with the aid of the OPEN B and...

Page 68: ...crush hazard due to the door movement When the drive is actuated the opening and closing processes must be monitored The garage door must be visible from the place of operation Make sure that no perso...

Page 69: ...time This way the garage door can be locked when closed During adjustments to the garage door or during power failure the garage door can be manually opened or closed III II I Fig 16 Disengaging and...

Page 70: ...and transmitter battery is empty Antenna is missing or misaligned No hand transmitter programmed Replace the hand transmitter battery Plug in align the antenna Program the hand transmitter see menu 1...

Page 71: ...Permanent signal at the START input Start signal is not detected or continuous pulse e g button jammed Error in setting the drive The travel path is too long Repeat setting procedure with menus 3 and...

Page 72: ...et and while reinserting the mains plug again 7 2 Cycle counter The cycle counter stores the number of OPEN CLOSE actions powered by the drive To read the meter hold the button C at the drive head for...

Page 73: ...ystem Location of door system Drive data Drive type Manufacture date Manufacturer Operating mode Door data Type Year of construction Serial no Door leaf weight Door dimensions Installation and initial...

Page 74: ...on and maintenance work must be documented in the enclosed inspection and test report The operating company owner is obliged to store the inspection and test report together with the documentation for...

Page 75: ...1 Springs State seat setting 2 1 1 Spring strips State 2 1 2 Spring break device State rating plate 2 1 3 Safety elements spring connector State seat 2 2 Wire cables State seat 2 2 1 Mounting State se...

Page 76: ...nsors Function state 5 5 Closing edge safety device Function state 6 0 Documentation of the operator owner 6 1 Rating plate CE marking complete readable 6 2 Door system s Declaration of Conformity com...

Page 77: ...g the integrated power disconnection is tested automatically WARNING Crush hazard at the door If the force limits are set too high there is a risk of personal injury The factory setting is 6 for openi...

Page 78: ...inity The addresses can be obtained from your municipality or local administration The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other fo...

Page 79: ...B and undertake to transmit it through our Documentation Department in response to a reasoned request by the competent national authorities Product model product B 1200 Product type Garage drive Year...

Page 80: ...l installation et le montage 87 4 2 Motorisations et accessoires 87 4 3 Composition de la fourniture 88 4 4 Pr paration du montage 89 4 5 Montage de la motorisation de porte de garage 90 4 5 1 D verro...

Page 81: ...fermeture manuelles de la porte de garage 107 5 4 Ouverture et fermeture de la porte de garage autres modes op ratoires 108 6 Recherche des d fauts 108 7 Affichage de diagnostic 109 7 1 R tablissemen...

Page 82: ...es vous permettre de mieux comprendre le sujet et les tapes des interventions Les repr sentations mat rielles sont montr es dans les illustrations titre d exemple et peuvent diff rer l g rement de l...

Page 83: ...ment pour l ensemble du corps humain 1 4 Symboles informatifs AVIS REMARQUE indique des informations importantes p ex dommages mat riels mais pas de dangers Information Les indications dot es de ce sy...

Page 84: ...pervision ou qu ils aient re u une instruction ad quate relative une utilisation sure de l appareil et qu ils aient compris les dangers li s cette utilisation Il est interdit aux enfants de jouer avec...

Page 85: ...ableau suivant T che Op rateur Personnel qualifi a dot d une formation ad quate p ex m canicien industriel lectricien qualifi b Mise en place montage mise en service X X Installation lectrique X Utili...

Page 86: ...toute remise sous tension 3 S assurer de l absence de tension Les travaux sur le syst me lectrique ne doivent tre effectu s que par un lectricien qualifi ou par des personnes sous les ordres et la sur...

Page 87: ...ail de guidage exemple de mod le c t motorisation 12 Bielle 4 Coulisseau mobile 13 Suspente centrale 7 Connecteur de rail de guidage exemple de mod le 16a Fixation au plafond t te de commande et d ent...

Page 88: ...P20 pour locaux secs uniquement Raccordement 230 V 50Hz Volume sonore 70 dB A Puissance absorb e Fabricant Novoferm tormatic GmbH Standby 4 W Eisenh ttenweg 6 Max en fonctionnement 410 W 44145 Dortmun...

Page 89: ...ent s arr te et repart dans la direction inverse afin de lib rer l obstacle La porte peut tre fer m e par le biais d une nouvelle impulsion 4 Installation et montage 4 1 Consignes de s curit pour l in...

Page 90: ...sition de la fourniture 1 T te de commande et d entra nement avec module LED 11 Console de connexion de la porte 2 Pignon moteur 12 Bielle 3 Rail de guidage exemple de mod le c t motorisation 13 Suspe...

Page 91: ...on secteur fourni a une longueur d environ 1 2 m V rifiez la stabilit de la porte resserrez les vis et les crous Contr lez la mobilit de la porte lubrifiez les arbres et les paliers La pr tension des...

Page 92: ...et la t te de commande et d entra nement 1 Ensuite fixez les fixations plafond 16 au plafond 6 Montez la bielle 12 entre le coulisseau mobile 4 et la console de jonction de la porte 11 7 Pour la prog...

Page 93: ...connectez la t te de commande et d entra nement de l alimentation lectrique en tirant la fiche de la prise Ne raccordez aucun c ble sous tension Seuls des contacts et des sorties relais flottants peu...

Page 94: ...2 REL LS 4 1 2 3 4 5 LS 4 1 2 I H G F E 8k2 I H G F E 24V 8k2 6 7 8 9 10 K 230V P J I H G F E P I H G F E REL 24V E43U 8k2 11 12 13 K L L N 1 N N N M M M N N N M M M K L M N O 14 O OSE WE WE GN BN BN...

Page 95: ...ion Ne pas raccorder de bouton poussoir 8 K Raccordement pour clairage ou t moin lumineux externe double isolation classe de protection II max 500 W accessoire 9 F I Alimentation 24 V DC max 100 mA pe...

Page 96: ...externe le blindage de celle ci doit tre reli la borne situ e c t F 4 8 Programmation de la t te de commande Dans cette section nous d crivons la programmation de base de l entra nement dans le cadre...

Page 97: ...fichage des points s allume 4 8 2 Menu 1 Fonction d marrage pour l metteur portatif D A1 Fig 9 Programmation de la fonction d marrage pour l metteur portatif 1 Appuyez une fois bri vement sur la touch...

Page 98: ...t tre programm s Par exemple 15x d marrage et 15x clairage Pour la programmation de la position d a ration et de l ouverture partielle voir menu 9 4 8 4 Effacement de tous les metteurs portatifs progr...

Page 99: ...position finale d ouverture souhait e Le cas ch ant ap puyez sur la touche FERMETURE C pour en corriger la position 4 Quand la porte de garage se trouve dans la position finale d ouverture sou hait e...

Page 100: ...ispara tre La course d apprentissage de l effort commence toujours par tir de la position finale de FERMETURE AVIS Nous recommandons de s lectionner le type de porte dans le menu 8 avant l apprentissa...

Page 101: ...ection pour revenir en position d OUVERTURE d s qu un contact avec un obstacle est d tect 3 Si la porte offre la possibilit de soulever une personne par ex ouvertures de plus de 50 mm ou surfaces hori...

Page 102: ...nes la livraison les valeurs r gl es sont 6 pour la fermeture et 4 pour l ouverture L effort au niveau du bord de fermeture principal ne doit pas ex c der 400 N 750 ms AVIS Nous recommandons de s lect...

Page 103: ...hes OUVERTURE B et FERMETURE C Valeur Dur e d clairage Temps de pr avis Clignotement 0 60 s 0 s non 1 120 s 0 s non 2 240 s 0 s non 3 0 s 0 s oui 4 0 s 3 s non 5 0 s 0 s non 6 0 s 3 s oui 7 90 s 3 s n...

Page 104: ...2 Porte basculante porte inclinable normale 3 Porte basculante porte inclinable course sensible 4 R glage universel programm en usine 5 Porte sectionnelle avec ferrure ressort de rappel Topspeed 6 Por...

Page 105: ...pulsion pendant la course de fermeture la porte stoppe et s ouvre nouveau 6 Fermeture automatique AR Une transmission d impulsion provoque toujours une ouverture de la porte Apr s coulement du du temp...

Page 106: ...rte 0 0 s 1 10 s 2 30 s 3 60 s 4 90 s 5 120 s 6 150 s 7 180 s 8 210 s 9 240 s 3 Appuyez sur la touche de programmation touche PROG D La valeur H s affiche 4 9 7 Menu H r glages STOPP A 1 S lectionnez...

Page 107: ...mani re bien visible sur la face int rieure de votre porte de garage WARNUNG Automatisches Tor Nicht im Bewegungsbereich des Tores aufhalten da sich das Tor unerwartet in Bewegung setzen kann WARNING...

Page 108: ...de d placement de la porte 5 2 Ouverture et fermeture de la porte de garage en fonctionnement normal La porte de garage peut tre actionn e au moyen de diff rents appareils de com mande metteur portati...

Page 109: ...t les remonter si la porte de garage doit tre man uvr e la main pen dant une p riode assez longue C est l unique fa on de verrouiller la porte de garage en position ferm e En cas de r glage de la port...

Page 110: ...que le moteur fonctionne L entra nement est d verrouill Reverrouiller la motorisation voir chapitre Ouverture et fermeture manuelles de la porte de garage La porte ne r agit pas l impulsion envoy e pa...

Page 111: ...Proc dez un nouveau r glage des positions finales La porte de garage ne s ouvre ou ne se ferme pas Interruption sur l entr e STOP A ou d clenchement d un dispositif de s curit externe ex portillon La...

Page 112: ...ON Le test du contact de portillon a chou Contr lez le c ble et les raccordements et bornes du contact de portillon 7 1 R tablissement des r glages d usine 1 Appuyez en m me temps sur les touches OUV...

Page 113: ...risation Date de fabrication Fabricant Mode de fonctionnement Caract ristiques de la porte Type Ann e de construction Num ro de s rie Poids du tablier Dimensions Installation premi re mise en service...

Page 114: ...s les travaux d inspection et d entretien doivent tre document s dans le cahier d inspection ci joint L exploitant propri taire est tenu de conserver soigneusement ce cahier d inspection au m me endro...

Page 115: ...t en cas de rupture du ressort tat plaque signal tique 2 1 3 Dispositifs de s curit assemblage par languette tat tenue 2 2 C bles m talliques tat tenue 2 2 1 Fixation du c ble tat tenue 2 2 2 Tambour...

Page 116: ...ques Fonctionnement tat 5 5 Tranche de s curit Fonctionnement tat 6 0 Documentation de l exploitant propri taire 6 1 Plaque signal tique tiquette CE compl te lisible 6 2 D claration de conformit du sy...

Page 117: ...matiquement AVERTISST Risque d crasement la porte En cas de r glage d une valeur trop lev e pour la limitation d ef fort il existe un risque de blessure pour les personnes la livraison les valeurs r g...

Page 118: ...peuvent vous en fournir les adresses La collecte s par e des appareils lectriques et lectro niques usag s permet leur r utilisation ventuelle le recyclage des mat riaux constitutifs et les autres for...

Page 119: ...les transmettre aux instances comp tentes des pays individuels par l interm diaire de notre service documentation Mod le produit B 1200 Type du produit Entra nement pour garage Premi re ann e de fabr...

Page 120: ...ting 126 4 Installeren en montage 126 4 1 Veiligheidsaanwijzingen voor installeren en montage 126 4 2 Aandrijvingen en accessoires 126 4 3 Leveringsomvang 127 4 4 Voorbereiding van de montage 128 4 5...

Page 121: ...al bedrijf 144 5 3 Garagedeur handmatig openen en sluiten 145 5 4 Garagedeur openen en sluiten overige modi 146 6 Foutzoeken 146 7 Diagnoseweergave 147 7 1 Fabrieksinstellingen herstellen 148 7 2 Cycl...

Page 122: ...eze montage en gebruikshandleiding dienen voor een beter begrip van de stand van zaken en de werkstappen De getoonde afbeeldingen zijn voorbeelden en kunnen in geringe mate afwijken van het werkelijke...

Page 123: ...schade maar niet op gevaren Info Aanwijzingen met dit symbool helpen u bij het snel en veilig uitvoeren van uw taken 2 Veiligheid Altijd de volgende veiligheidsaanwijzingen opvolgen WAARSCHUWING Letse...

Page 124: ...ingen is elke aansprakelijkheid van de fabrikant of aannemers hiervan uitgesloten 2 1 Bedoeld gebruik Het product is uitsluitend ontworpen voor het openen en sluiten van garagedeu ren met gewichts of...

Page 125: ...edraden de correcte werking van elektrische com ponenten waarborgen en mogelijke gevaren in de omgang met elektrische en elektronische systemen kunnen herkennen 2 4 Gevaren die kunnen uitgaan van het...

Page 126: ...ingstraject van de garagedeur Onderbreek de procedure alleen bij gevaar 3 Productbeschrijving 3 1 Algemeen productoverzicht 4 1 17 7 9 10 8 11 20 13 3 12 16b 16a Afb 1 Productoverzicht 1 Aandrijfkop m...

Page 127: ...N Max belastbaarheid 1000 N Beschermingsgraad IP20 alleen voor droge ruimten Aansluitwaarden 230 V 50Hz Geluidssterkte 70 dB A Opgenomen vermogen Fabrikant Novoferm tormatic GmbH Stand by 4 W Eisenh t...

Page 128: ...e de deur in de tegengestelde richting voor het vrijgeven van de hindernis De deur kan door het opnieuw geven van een puls weer worden gesloten 4 Installeren en montage 4 1 Veiligheidsaanwijzingen voo...

Page 129: ...14 17 15 19 11 13 10 Afb 4 Leveringsomvang 1 Aandrijfkop met LED module 11 Deuraansluitconsole 2 Aandrijfrondsel 12 Stuurkoppelstang 3 Looprail modelvoorbeeld aandrijfzijde 13 Middenophanging 4 Loopsl...

Page 130: ...meegeleverde netaansluitkabel is ca 1 2 m lang Controleer de stabiliteit van de deur de bouten en moeren bij de deur natrekken Controleer de deur op een probleemloze loop smeer de assen en lagers De v...

Page 131: ...ng 13 en aan de aandrijfkop 1 Monteer de plafondbevestigingen 16 daarna aan het plafond 6 Monteer de stuurkoppelstang 12 tussen de loopslede 4 en deuraansluitconsole 11 7 Voor de programmering de afde...

Page 132: ...en van de afdekking van de aandrijfkop de voe dingsspanning onderbreken door de stekker uit het stopcontact te trekken Geen spanningvoerende leidingen aansluiten Alleen potentiaal vrije schakelaars en...

Page 133: ...1 2 1 2 I H G F E 8k2 REL LS 4 1 2 3 4 5 LS 4 1 2 I H G F E 8k2 I H G F E 24V 8k2 6 7 8 9 10 K 230V P J I H G F E P I H G F E REL 24V E43U 8k2 11 12 13 K L L N 1 N N N M M M N N N M M M K L M N O 14 O...

Page 134: ...nsluiting voor externe verlichting met dubbele isolatie of signaallamp beschermklasse II max 500 W accessoires 9 F I Voedingsspanning 24 V DC max 100 mA permanent 10 P Aansluiting voor Mobility module...

Page 135: ...plaatsen LET OP Bij gebruik van een externe antenne moet de afscherming worden aangesloten op de hiernaast liggende klem F 4 8 Aandrijfkop programmeren In deze paragraaf wordt de basisprogrammering va...

Page 136: ...fkop verwijderen 5 Verbind het netsnoer met een netstopcontact De puntindicatie gaat branden 4 8 2 Menu 1 startfunctie voor de handzender D A1 Afb 9 Startfunctie voor de handzender programmeren 1 Een...

Page 137: ...aal 30 codes kunnen worden ingeleerd Bijvoorbeeld 15x start 15x verlichting Voor de programmering van de ventilatiestand en gedeeltelijke opening zie menu 9 4 8 4 Wissen van alle bij de aandrijving ge...

Page 138: ...deur de gewenste eindpositie OPEN heeft bereikt Indien nodig op de DICHT knop C drukken om de po sitie te corrigeren 4 Staat de garagedeur in de gewenste eindpositie OPEN drukken op de pro grammeerkno...

Page 139: ...weergave 0 uit gaan De krachtinleerfase begint altijd vanuit de eindpositie DICHT LET OP Wij adviseren v r de krachtinleerfase het betreffende deurtype in menu 8 te selecteren B Afb 14 Krachtinleerfas...

Page 140: ...terug naar de eindpositie OPEN zodra contact met een hindernis wordt gedetecteerd 3 Kan de deur eventueel personen optillen bijv openingen groter 50 mm of mogelijke stavlakken moet de krachtbegrenzing...

Page 141: ...etsel In de aflevertoestand is de ingestelde waarde bij het openen 6 en bij het sluiten 4 De kracht bij de hoofdsluitrand mag niet groter zijn dan 400 N 750 ms LET OP Wij adviseren v r de krachtinleer...

Page 142: ...T C Waarde Verlichtingstijd Voorwaarschuwingstij d Knipperfunctie 0 60 s 0 s Nee 1 120 s 0 s Nee 2 240 s 0 s Nee 3 0 s 0 s Ja 4 0 s 3 s Nee 5 0 s 0 s Nee 6 0 s 3 s Ja 7 90 s 3 s Nee 8 90 s 3 s Ja 9 0...

Page 143: ...selecteerd 2 De instelling indien nodig aanpassen met de knoppen OPEN B en DICHT C Menuwaarde Deurtype 0 Deur met twee deurbladen 1 Niet uitzwenkende deur Canopy 2 Draaideur kanteldeur normaal 3 Draai...

Page 144: ...e deur naar de eindpositie OPEN Nog een puls tijdens het openen heeft geen invloed en de deur gaat verder open Na een puls in de OPEN positie gaat de deur dicht Bij een puls tijdens het sluiten stopt...

Page 145: ...60 s 4 90 s 5 120 s 6 150 s 7 180 s 8 210 s 9 240 s 3 Op de programmeerknop PROG knop D drukken De waarde H wordt weergegeven 4 9 7 Menu H Instellingen STOP A 1 Kies het menupunt H Na ca 2 seconden k...

Page 146: ...ften De voor de gebruikslocatie geldende lokale ongevalpreventievoorschriften en algemene veiligheidsbepalingen opvolgen Bewaar handzenders buiten bereik van kinderen WAARSCHUWING Stoot en knelgevaar...

Page 147: ...e spankracht hebben Neem contact op met de betreffende leverancier fabrikant LET OP Tijdens het installeren van het systeem zijn vergrendelingselemen ten van de garagedeuraandrijving gedemonteerd Deze...

Page 148: ...et correct ingesteld Hindernis verwijderen Eindposities DICHT opnieuw laten instellen Aandrijving beweegt niet terwijl motor draait De aandrijving is ontgrendeld Aandrijving weer vergrendelen zie hoof...

Page 149: ...ragedeur opent of sluit niet Onderbreking op STOP A of activering van externe veiligheidsinrichting bijv loopdeur Garagedeur sluit niet Onderbreking op STOP B of activering externe veiligheidsinrichti...

Page 150: ...pdeurcontact 7 1 Fabrieksinstellingen herstellen 1 Tegelijkertijd op de knoppen OPEN B en DICHT C drukken C B Afb 17 Fabrieksinstellingen 2 Beide knoppen ca 3 seconden ingedrukt houden terwijl u de ne...

Page 151: ...s Aandrijvingstype Productiedatum Fabrikant Bedrijfsmodus Deurgegevens Type Bouwjaar Serienummer Gewicht deurblad Afmetingen Installeren eerste inbedrijfstelling Firma installatiebedrijf Naam installa...

Page 152: ...n onderhoudsactiviteiten moeten worden gedocumenteerd in het meegeleverde inspectie en controlerapport De exploitant eigenaar is verplicht het inspectie en controlerapport samen met de documentatie vo...

Page 153: ...instelling 2 1 1 Veerbanden Toestand 2 1 2 Veerbreukbeveiliging Toestand typeplaatje 2 1 3 Veiligheidsinrichtingen veerverbinding Toestand vastzitten 2 2 Staalkabels Toestand vastzitten 2 2 1 Kabelbev...

Page 154: ...len Werking toestand 5 5 Sluitrandbeveiliging Werking toestand 6 0 Documentatie exploitant eigenaar 6 1 Typeplaatje CE markering Volledig leesbaar 6 2 Conformiteitsverklaring deurinstallatie Volledig...

Page 155: ...t WAARSCHUWING Knelgevaar bij de deur Bij een te hoge instelling van de krachtbegrenzing bestaat gevaar voor persoonlijk letsel In de aflevertoestand is de ingestelde waarde bij het openen 6 en bij he...

Page 156: ...aar De adressen zijn verkrijgbaar via uw gemeente of provincie Door het gescheiden inzamelen van elektronische of elektrische apparaten wor den recyclen materiaalhergebruik resp ander vormen van herge...

Page 157: ...umentatieafdeling te overhandigen aan de offici le instanties Productmodel product B 1200 Producttype Garagedeuraandrijving Bouwjaar vanaf 2019 Van toepassing zijnde EG EU richtlijnen 2014 30 EU 2011...

Page 158: ...164 4 1 Sikkerhedsanvisninger for installation og montering 164 4 2 Aktuator og tilbeh r 164 4 3 Leveringsomfang 165 4 4 Forberedelse af montage 166 4 5 Montering af garageportens aktuator 167 4 5 1 F...

Page 159: ...lukkes med h nden 183 5 4 bning og lukning af garageporten andre driftstyper 184 6 Fejls gning 184 7 Diagnosedisplay 185 7 1 Genoprettelse af fabriksindstillingerne 186 7 2 cyklust ller 186 8 Inspekt...

Page 160: ...faktiske udseende 1 2 Piktogrammer og signalord Vigtige oplysninger i denne h ndbog er markeret med f lgende piktogrammer FARE FARE angiver en fare der hvis den ikke undg s vil resultere i d d el ler...

Page 161: ...nde undg s under arbejdet med og p produktet L s og f lg alle sikkerhedsanvisninger og instruktioner Overhold alle anvisninger i denne betjeningsvejledning med hensyn til tilsigtet brug Opbevar alle s...

Page 162: ...er ikke tilladt Producenten p tager sig intet ansvar for skader p personer eller genstande som skyldes rimelig forudsigelig forkert brug eller manglende overholdelse af in struktionerne i denne monte...

Page 163: ...p nding Livsfare p grund af elektrisk st d ved ber ring af str mf rende dele Hvis det er n dvendigt at udf re arbejde p det elektriske sy stem skal f lgende sikkerhedsregler overholdes 1 Frikobling 2...

Page 164: ...Konsol til tilslutning af port 3 L beskinne modeleksempel drivside 12 St dstang 4 Sl de 13 Midteroph ng 7 Forbindelsesstykke til l beskinne modeleksempel 16a Loftholder aktuatorhoved 8 L beskinne mod...

Page 165: ...ne 1000 N Beskyttelsesklasse IP20 kun til t rre rum Tilslutningsv rdier 230 V 50Hz Lydstyrke 70 dB A Str mforbrug Producent Novoferm tormatic GmbH Sleep 4 W Eisenh ttenweg 6 Maks drift 410 W 44145 Dor...

Page 166: ...ngen stopper aktuatoren og be v ger sig i modsat retning for at frig re forhindringen Porten kan lukkes igen ved at generere en ny impuls 4 Installation og montering 4 1 Sikkerhedsanvisninger for inst...

Page 167: ...8 16 14 17 15 19 11 13 10 Fig 4 Leveringsomfang 1 Aktuatorhoved med LED modul 11 Konsol til tilslutning af port 2 Drivtandhjul 12 St dstang 3 L beskinne modeleksempel drivside 13 Midteroph ng 4 Sl de...

Page 168: ...Det medf lgende tilslutningskabel til str mforsyningen er ca 1 2 meter langt Kontroll r portens stabilitet og eftersp nd bolte og m trikker p porten Kontroll r at porten bev ger sig uden problemer og...

Page 169: ...det 1 Monter derefter loftholderne 16 i loftet 6 Monter st dstangen 12 mellem sl den 4 og konsollen til tilslutning af porten 11 7 bn afd kningen p aktuatorhovedet vha en skruetr kker eller et lignend...

Page 170: ...mf rende dele Afbryd str mforsyningen til aktuatorhovedet ved at tr kke stikket ud af stikkontakten f r d kslet bnes Tilslut ikke sp ndingsf rende ledninger Der m kun tilsluttes po tentialfrie knapper...

Page 171: ...1 2 I H G F E 8k2 REL LS 4 1 2 3 4 5 LS 4 1 2 I H G F E 8k2 I H G F E 24V 8k2 6 7 8 9 10 K 230V P J I H G F E P I H G F E REL 24V E43U 8k2 11 12 13 K L L N 1 N N N M M M N N N M M M K L M N O 14 O OSE...

Page 172: ...ing til ekstern belysning med isolerende beskyttelse eller signallampe beskyttelsesklasse II maks 500 W ekstraudstyr 9 F I Sp ndingsforsyning 24 V DC maks 100 mA permanent 10 P Tilslutning til Mobilit...

Page 173: ...sk rmningen tilslut tes p den tilst dende klemme F 4 8 Programmering af aktuatorens hoved I dette afsnit beskrives den grundl ggende programmering af aktuatoren i forbin delse med installationen Progr...

Page 174: ...ikkontakt Punktindikatoren t nder 4 8 2 Menu 1 Startfunktion for h ndholdt sender D A1 Fig 9 Programmering af startfunktion for h ndholdt sender 1 Tryk en gang hurtigt p programmeringsknappen knappen...

Page 175: ...trin 1 BEM RK Der kan indl res maks 30 koder f eks 15x start 15x lys Programmering af udluftningspositionen og del bningen se menu 9 4 8 4 Sletning af alle h ndholdte sendere som er programmeret i akt...

Page 176: ...ld knappen OP trykket indtil garageporten har n et den nskede bnings position Tryk evt p knappen NED C for at korrigere positionen 4 Tryk p programmeringsknappen knappen PROG D n r garageporten be fin...

Page 177: ...raftindl ringsk rslen begynder altid fra endepositionen NED dvs med lukket port BEM RK Vi anbefaler at v lge den p g ldende porttype i menu 8 f r kraftindl ringsk rslen B Fig 14 Kraftindl ringsk rsel...

Page 178: ...orten stopper og k rer tilbage til endepositionen OP s snart en forhindring konsta teres 3 Hvis det er muligt at l fte personer med porten f eks hvis bningen er st rre end 50 mm eller den har tr defla...

Page 179: ...Ved leveringen er den indstillede v rdi for bning 6 og 4 for lukning Kraften p hovedlukkekanten m ikke overstige 400 N 750 ms BEM RK Vi anbefaler at v lge den p g ldende porttype i menu 8 f r kraftind...

Page 180: ...B og NED C V rdi Tidsindstilling for lampe Varslingstid Blinkefunktion 0 60 sek 0 sek nej 1 120 sek 0 sek nej 2 240 sek 0 sek nej 3 0 sek 0 sek ja 4 0 sek 3 sek nej 5 0 sek 0 sek nej 6 0 sek 3 sek ja...

Page 181: ...fterne 2 Just r eventuelt indstillingen ved hj lp af knapperne OP B og NED C Menuv rdi Porttype 0 Dobbelt fl jport 1 Port der ikke svinger ud Canopy 2 Almindelig svingport vippeport 3 Svingport vippep...

Page 182: ...ition starter aktuatoren og k rer porten til slutpositionen OP En yderligere impuls under opk rslen p virker ikke porten og porten bnes mere Efter en impuls i OP positionen lukkes porten Ved en impuls...

Page 183: ...ek 4 90 sek 5 120 sek 6 150 sek 7 180 sek 8 210 sek 9 240 sek 3 Tryk p programmeringsknappen knappen PROG D V rdien H vises 4 9 7 Menu H Indstillinger for STOPP A 1 V lg menupunktet H Efter ca 2 sekun...

Page 184: ...mmelser Lokalt g ldende ulykkesforebyggende regler og almindelige sikkerhedsbestemmelser for maskinens anvendelsesomr de skal overholdes Opbevar den h ndholdte betjening uden for b rns r kkevidde ADVA...

Page 185: ...tilf ldet BEM RK Ved installation af systemet er l seelementet p garageportens ak tuator blevet afmonteret Dette skal genmonteres hvis garagepor ten skal betjenes manuelt i en l ngere periode Kun p d...

Page 186: ...st op L s igen aktuatoren se kapitlet Garageporten bnes og lukkes med h nden Porten reagerer ikke p impulserne fra den h ndholdte betjening men reager n r den betjenes med trykknapperne eller andre im...

Page 187: ...ydelse p STOPP A eller udl sning af den eksterne sikkerhedsanordningen f eks indbygget d r i garageport Garageporten lukker ikke Afbrydelse p STOPP B eller udl sning af den eksterne sikkerhedsanordnin...

Page 188: ...rten mislykkedes Kontroll r ledningerne og klemmeforbindelserne p kontakten p den indbyggede d r i garageporten 7 1 Genoprettelse af fabriksindstillingerne 1 Tryk samtidig p knappen BN B og LUK C C B...

Page 189: ...toren Aktuatortype Fremstillingsdato Producent Driftstype Portens specifikationer Type Fremstillings r Serienummer Portbladets v gt M l Installation f rste ibrugtagning Firma installationsfirma Navn i...

Page 190: ...oldelsesopgaver skal dokumenteres i den vedlagte eftersyns og vedligeholdelsesprotokol Brugeren ejeren er forpligtet til at opbevare inspektions og afpr vningsprotokollen sikkert sammen med dokumentat...

Page 191: ...and typeskilt 2 1 3 Sikkerhedsanordninger fjederforbindelse Tilstand placering 2 2 Tovv rk Tilstand placering 2 2 1 Tovoph ng Tilstand placering 2 2 2 Tovtromle 2 3 Faldsikringsanordning Tilstand 2 4...

Page 192: ...Lukkekantsikring Funktion tilstand 6 0 Brugerens ejerens dokumentation 6 1 Typeskilt CE m rkning komplet l selig 6 2 Overensstemmelseserkl ring for portsystem komplet l selig 6 3 Installation drift o...

Page 193: ...gede kraftbegr nser automatisk ADVARSEL Fare for knusning i porten Hvis kraftbegr nseren er for h jt indstillet er der for per sonskader Ved leveringen er den indstillede v rdi for bning 6 og 4 for lu...

Page 194: ...dstyr Adresserne p disse indsamlingsdepo ter kan f s hos den lokale kommunalforvaltning Den separate indsamling af af fald af elektrisk og elektronisk udstyr er beregnet til at muligg re genbrug samt...

Page 195: ...elte stater ved henvendelse til vores dokumentationsafdeling Produktmodel produkt B 1200 Produkttype Garageaktuator Konstruktions r fra 2019 Relevante EF EU direktiver 2014 30 EU 2011 65 EU Overholdte...

Page 196: ...Novoferm tormatic GmbH Eisenh ttenweg 6 44145 Dortmund...

Reviews: