- 27 -
9
Unused
10
No bar found from left
11
No bar found
12
No plausible structure code I2of5
13
No plausible structure code 39
14
Wrong type of code, no accordance with the desired code
15
No valid code was found
16
No correct code structure decoding error code I2of5
17
No correct code structure decoding error code 39
Maintenance
The topCam6500 is to a large extent maintenance-free. Merely the glass pane should
occasionally be checked for dirt and staining and cleaned if necessary.
16.
Trouble shooting
The switching outputs do not work, but 24 V are measurable at the blank trigger
input instead.
This effect occurs when the supply of gate in- and outputs has a wrong polarity.
The topCam6500 receives commands and also reacts to a trigger signal. However, no
scanning results are transmitted. The topCam6500 is connected to the maintenance
interface.
In normal mode no scanning results are transmitted at the maintenance interface. The item
TopCamControl activates an operating mode upon start, where the scanned data as well as
additional information are transmitted via the maintenance interface. This operating mode can
be switched on by entering the command ’DE:W:1’, thus producing a record of scanning
results. This output can be switched off again by entering the command ’DE:W:0’.