background image

INSTALLATION MANUAL

FEATURES

- Antimask autoset

- Digital sampling of the signal

- Modes of detection: EI  OR - AND

- Detection sensibility selectable

- Memories of alarm type

- Interactive LED OFF

- Antifliker

- Solid state relays

- Microwave stripline with pulse emission

- Fresnell lens 18 zones on 4 planes with look down zone

- Vertical adjust

- Sealed optics

- Wall tamper

- Cover 90 degrees for 15 Mt

- Corner, wall or bracket mounting

- Bracket (optional) antiviolation

with regulation 90°horiz. 30°vert

The 

AKAB-W

is a motion detector with 3 modes of detection,

equipped with two high quality sensors: 
A) A dual element infrared (IRP)       
B) A microwave microstrip (uW).
Both the sensors are supervised by a microcontroller that
optimises performance.
The 

AKAB-W

offers the advantage of 3 different modes of

detection with two levels of sensibility, which enables the choice

of the most useful for the area to be protected.
In addition to the traditional AND / OR the 

AKAB-W

offers the

EI modality recommended for installation in area where is
possible sabotage with spray varnish on the IRP lens.
Furthermore the 

AKAB-W

offers a multitude of function among

which is the  Antimask autoset and memory of alarm type.

SYSTEM INSTALLATION    

Select the best possible location in the room for both the IRP
and uW technologies. If possible, aim the unit towards the
room’s interior and away from windows, moving machinery,
heating and cooling sources

WALL MOUNTING                  

The maximum range is obtained at mounting height of 2,10 Mt.,
Vertical Adjust in A position (fig 8); It’s possible to mount the
detector at a height up to 4 Mt (fig 6-7).      
Make sure that the sensor has a clear line of sight to all areas
you wish to protect. Remove the front cover, loosen the screw
and remove the circuit board.
Engrave, as need, the keyholes on the back cover (fig 1), knock
out the Wall Tamper keyhole if required (CEI 79-2 II°Liv.) cut out
the wire keyhole. 
Sign the holes on the wall having care to sign the hole Wall
Tamper at the centre of the keyhole. Make the fixing hole
(6mm) on the wall. Fix the screw Wall tamper at the wall leaving
the screw head out of 5/6 mm. Run the cable through the wire
keyhole.
Fix the back cover on the wall with the screws furnished; make
sure that the screws are securely fixed in their keyholes. Apply
the microswitch Wall Tamper in his housing (fig.2), fold up the
lever so that will remain pushed by the screw and than fix the

1

Reviews: