background image

tamper cover with the furnished screw.  
Mount  the circuit board.           
Connect the microswitch to the Wall Tamper connector (fig 4).
Wire the cable on the terminals.        

BRACKET MOUNTING (OPTIONAL)  

Fix the grip A (fig.3) on the wall with the screw furnished. Make
up the bracket inserting the grip B into the grip A. Remove the
front cover, loosen the screw and remove the circuit board.
Engrave the bracket keyhole and the wire keyhole on the
bottom of the back cover (Fig.1), and with the screw furnished
fix the bottom of the back cover on the bracket.
Direct the back cover to the wanted direction then block it by
clamping the screw.  Run the cable through the house.   
Mount the circuit board.            
Wire the cable on the terminals.                   

Apply power to the AKAB. A 60” self test will be performed;
during this period the leds will flash alternately. At the end
proceed with the calibration.          

TEST (CALIBRATION)               

DIP SWITCH N°1 in pos.OFF
(Antimask OFF)

DIP SWITCH N°5 in pos.OFF
(Led enabled)

Attention: 
in this modality the ANTIMASK function is disabled

uW
Set the trimmer at minimum, (range min. 4mt, max 15mt), go to
the border of the protected area and, with leds off, move
towards the unit to verify the detection of the uW and set
sensitivity; the green led will light up. Whenever the green led
will not light up increase the range of the uW by turning the
trimmer clockwise;   repeat the test until the required condition
is obtained.       

N.B. REGULATION OF THE uW: the range must be regulated
to the minimum necessary because the uW can penetrate walls
and detect from outside the protected area.          
NOTE: regulating the uW at a high range does not improve
detection in the desired area.

IRP.               
Mount the front cover and, when leds are off move in the area
where IRP must verify intrusion. The lighting of the yellow led
enables verification of no shadow zones in the protected area.  
Putting all the Dip Switches in pos. OFF the detector will be set
to work in the STANDARD* mode.

2

Reviews: