7-3
7 PARAMETERS SETTING MODE
7.1.2 Parameters for communication
Factory default settings are indicated with underlines.
Menu
Selecting Item
Contents
1.B. Rate
1200 / 2400 / 4800 /
9600
Select the baud rate.
2.Data. L
7 / 8
Select the data length seven digits or eight digits.
3.Parity
none / odd / even
Select the parity bit.
4.Stop Bit
1 / 2
Select the stop bit.
5.Delimit
ETX / CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
6.REC-A/B
A / B
Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
7.Protocol
OFF / ON
When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard
8.NEZ-REC
Std / Exp
Record coordinates in standard or Data with slope distance
and horizontal angle data.
Summary of Contents for GTS-600 Series
Page 2: ......
Page 120: ...10 SETTING ATMOSPHERIC CORRECTION 10 4...
Page 121: ...10 SETTING ATMOSPHERIC CORRECTION 10 5...
Page 143: ......