3-7
3 STANDARD MEASUREMENT MODE
3.2.5 Fine/ Tracking / Coarse Measuring Mode
•Fine mode
: This is a normal distance measuring mode.
Measurement time 0.2mm mode : approx.2.8 seconds
1 mm mode : approx.1.2 seconds
The unit to be displayed is 0.2mm or 1mm. (0.001ft or 0.005ft)
•Tracking mode : This mode measures in shorter time than in fine mode.
Use this mode for stake out measurement. It is very useful when tailing the moving
object or carrying out stake-out work.
Measurement time : approx. 0.4 seconds
The unit to be displayed is 10mm. (0.02ft)
•Coarse mode
: This mode measures in shorter time than in fine mode.
Use this mode for the objects which may be slightly unstable.
Measurement time : approx. 0.7 seconds
The unit to be displayed is 1mm. (0.005ft)
Operating procedure
Operation
Display
1
Collimate the center of prism.
Collimate
2
Select the measurement mode by pressing
[F1](SD) or [F2](HD) key.
Example:Horizontal distance
Measuring starts.
[F2]
3
Press [F2](MODE) key , the mode changes
to Coarse mode.
Press [F2](MODE) key again, the mode
changes to Tracking mode. *1)
[F2]
[F2]
*1) Every time pressing [F2](MODE) key, the mode will be changed in procedure
3
.
V: 90
°
10'20"
HR: 120
°
30'40"
SD HD NEZ 0SET HOLD P1
↓
V : 90
°
10'20"
HR: 120
°
30'40" PSM 0.0
HD: < PPM 0.0
VD: (m) *F.R
MEAS MODE VH SD NEZ P1
↓
V : 90
°
10'20"
HR: 120
°
30'40" PSM 0.0
HD: PPM 0.0
VD: (m) T.R
MEAS MODE VH SD NEZ P1
↓