4-27
4 PROGRAM MODE
5
The next screen appears to type in the
backsight point number. If the point number is
not stored in the job, an input screen appears
to type in the coordinates. If the point number
with coordinates are stored in the job the next
screen appears, step 6, with the backsight
direction.
[F6]
Type
Backsight
Point
Number
If the point number is not stored in
the job, this screen appears. Type in
the coordinate values.
6
If the backsight direction is correct, sight the
instrument on the backsight point and press
[F5] (YES) to set the direction. Press [F6]
(NO) returns back to the “Setting Backsight
Point” prompt on Step 5.
7
The next screen is to input the instrument
height. Type in the instrument height and
press the (ENT) key.
[F5]
Type
Inst.
Height
8
This screen is to input the side shot point
number. Type in the point number and press
the (ENT) key.
(ENT)
9
Type in the prism height and press the (ENT)
key.
Type
Prism
Height
10
Type in the side shot point number. Sight the
instrument on the side shot point and when
ready, press [F5] (YES) to measure and
collect the data. If you press [F6] NO, the
software will return back to the screen to input
the side shot point number.
(ENT)
Type
Shot
Point
Number
11
After pressing the [F5] key, the instrument will
measure the side shot point.
[F5]
Setting Backsight Point
PT#:
Alpha SPC <- ->
↑
↓
3
Setting Direction Angle
BS-T-POINT:
N :
E :
EXIT BS
Setting Direction Angle
BS
H(B) : 225°00'00"
>Set OK?
YES NO
New Point (Side Shot)
Inst.Ht:
EXIT BS
0.000
New Point (Side Shot)
PT#:
Alpha SPC <- ->
↑
↓
New Point (Side Shot)
R.Ht :
EXIT BS
0.000
New Point (Side Shot)
PT#:3
>Sight?
YES NO
HR: 225°00'00"
HD * <<
HV :