4-19
4 PROGRAM MODE
Receive Coordinates
The receive coordinate option receives jobs from the PC to the GTS-600. Before receiving any jobs,
make sure that the communication parameters in the instrument match the software parameters on the
PC software.
Operating procedure
Operation
Display
1
From the Job Manager menu, page 1, press
[F6] key to select page 2.
2
Press [F1] Transfer Jobs
[F6]
3
To receive a job press [F1].
4
Press [F5] (YES). Pressing [F6] (NO) returns
to the Job Manager menu.
5
A warning message will appear if a job exists
in memory. If you select [F5] (YES) to
overwrite the job, the current job will be
erased. If you do not want to overwrite the
current job, press [F6] (NO). If there are no
jobs in memory the receiving coordinate data
screen will appear as in step 7. For the
example press [F6] (NO).
[F1]
[F1]
[F5]
6
The next screen continues with the receive
job option and allows for another job to be
received. Pressing [F5] (YES) will add the job
received from the PC to memory without
erasing the current file. Pressing [F6] will
abort the receive option and return back to
page two of the Job Manager menu. For this
example press [F5] (YES). On the PC
execute the send option.
[F5]
7
On the receiving screen, the asterisk (*)
appears with the cursor blinking over the
asterisk. To stop the data transfer, press [F6]
(STOP). When the job is completely received
the Job Manager page 2 menu appears.
[F5]
Job Manager (Pg 1/2)
F1 View Memory
F2 Erase a Block of Point
F3 Erase One Point
F4 Create Another Job
↓
Job Manager (Pg 2/2)
F1 Transfer Jobs
F2 Rename Job
F3 Delete a Job
F4 Delete All Jobs
↑
Transfer Coordinate data
F1 Receive Coords.
F2 Send Coords.
F3 Comm Protocol
Transfer Coordinate data
Receive Coords.
>Ready
YES NO
Warning!!
Coordinate data file
already exists
>Overwrite ?
YES NO
Continue
Coordinate data file
already exists
>Another Job ?
YES NO
Transfer Coordinate data
Receive Coords.
*
>Receiving STOP