63
10. MEASURING (SCANNING)
Recommended search width setting
• Select the search width that meets your usage condition.
• Type of target
Setting the target height
Coordinate points on the ground can be registered (combining multiple sets of scanned data) as
the tie point (the connecting point) by entering the target height.
Set the target height as follows:
Distance to the
scanning target (m)
Search width
(degrees)
Target sheet
2-5
2.5
Small
5-10
1.0
Small
10-20
1.0
Small, medium
20-50
0.5
Small, medium, large
50-100
0.5
Medium, large
100-200
0.5
Large
Target
Distance to the
scanning target (m)
Size (m)
Target sheet (Large)
50-200
0.12
Target sheet (Medium)
10-100
0.06
Target sheet (Small)
2-50
0.03
Prism
10-100
Prism-2
Prism-5
Target height
Target coordinate
Tie point