55
9. STATION SETTINGS
8. Press
next to the backsight point (BS)
name, and then select the backsight point name
and the coordinate in the same manner as the
occupied point.
At this point, if you want to change the backsight
point name read from the coordinate file, tap the
input-editor of the backsight point name and
enter a different backsight point name.
9. Press [BS Scan].
The image will be displayed.
10.Enter the backsight point name (BS0002) in the
input-editor
on top of the screen.
For details of setting “ScnAng” and “HR”,
“10.1 Target Scanning”
11. Press
to switch the camera to "Tele"
and tap the target at the backsight point.
“Explanation of the buttons” on page 61
The instrument will automatically turn to the
object which will be displayed around the middle
of the screen. While doing this, the horizontally
rotating part and the turn of the scanner unit will
be locked.
To unlock, turn the horizontally
rotating part or the scanner unit manually.
12.Press [Start], Start/Stop scan key or collimating
position setting key.
• Sometimes “Internal calibration Please wait ...” is
displayed.
• When
is pressed, it will take a while to stop.