16
About the setting method of the type setting of "Time signal / Event Output 1" and the type setting of
"Run Signal Output / Event Output 2".
Action types (to be set by using the
▽
key)
Additional functions (to be set by using the
△
key)
Nil
<"Time signal / Event Output 1" type setting>
If this is selected, it will be a Time signal.
<"Run Signal Output / Event Output 2" type setting>
If this is selected, the output will be during operation.
No additional functions
Deviation upper and lower limit event
Output held
Deviation upper limit event
Standby sequence
Deviation lower limit event
Output held + standby sequence
Deviation upper and lower limit range event
Absolute value upper and lower limit event
Absolute value upper limit event
Absolute value lower limit event
Absolute value upper and lower limit range event
⑦
Event temperature setting mode
- This mode will set the event temperature.
- Use the PATT./STEP key to select an Event Output 1 Lower Limit "
", an Event Output
1 Upper Limit "
", an Event Output 2 Lower Limit "
" and an Event Output 2
Upper Limit "
" (This may not be displayed depending on the type of action selected for
an Event Output.)
* If no key is pressed for 10 seconds after the temperature setting is changed, then the product will
switch automatically to "reset mode."
From reset mode
Hold the
▽
key and the PATT./STEP
key down simultaneously.
Set "Event Output 1 lower limit setting".
Set "Event Output 1 upper limit setting".
Press the PATT./STEP key.
PV
SV
PV
SV
Press the PATT./STEP key.
Set "Event Output 2 lower limit setting".
PV
SV
Set "Event Output 2 upper limit setting".
PV
SV
Press the PATT./STEP key.
Press the PATT./STEP key.
⑧
Control setting
mode
- This mode will set the control setting
mode (during operation only).
PV
□
SV