![Toa VX-3308WM Operating Instructions Manual Download Page 43](http://html.mh-extra.com/html/toa/vx-3308wm/vx-3308wm_operating-instructions-manual_1123506043.webp)
Chapter 2
INDICATOR STATUS OF REMOTE MICROPHONES
2-
30
2.9. Indicator State at the Time of Failure Output Reset
When the VX-3000 system is set to enable "Surveillance function," the failure output reset function can be
assigned to a function key.
When the failure output reset function has been assigned to the Function key, the failure status indicator can be
reset by pressing the key. The indicator to the left of the key lights only when the key is pressed.
Notes
• For instructions on setting the surveillance function, see the separate Setting Software Instructions, "BASIC
SETTINGS."
• For instructions on assigning functions to function keys, see the separate Setting Software Instructions,
"EVENT SETTINGS."
Key ON/OFF Indicator
(Always unlit, not used)
Function key (Failure Output Reset key)
Indicator meanings are as follows:
Indicator
Status
Meaning
Key ON/OFF Indicator
Unlit
When the function key is not pressed
Lights green
When the function key is pressed (as long as it is pressed)