TA 220
38 / 64
Fault
Cause
Remedy
Plastic straps not sealed
properly, the seal is not
OK. The upper strap is
not cut completely or it is
irregular.
Cutter blade and/or welding
platelet worn or defective.
Perform visual inspection; if
required, replace cutter blade
and/or welding platelet.
The welding platelet is polluted
and slips over the strap.
Clean the welding platelet.
Welding time too short.
Check the welding time and enter
a higher value, if applicable.
Li-Po storage battery defective or
insufficiently charged.
Check charge of Li-Po storage
battery and recharge or, if req'd,
replace it.
Welding motor and/or board
defective.
Check welding motor and/or
board; if damages are visible,
contact TITAN service.
Use of inappropriate plastic strap.
Check plastic strap, does it meet
necessary requirements? If not,
use plastic strap meeting the
requirements of the tool.
During welding both
straps are cut.
Welding time too long and/or
strap tension too strong.
Correct value set on the
keyboard display downward.
Lower strap holding platelet worn
or polluted.
Clean strap holding platelet or
replace it, if required.
Lever 2 (welding) has
been actuated, but the
motor does not start the
welding operation.
Loose cable connection of the
microswitch or it is not activated
by the cam or it is defective.
Check micro switch
(90)
, it is
found below button 1
(91)
.
Should you detect visible
damage, contact TITAN service
dept.
Job data like tensioning
force and welding time
cannot be entered and do
not remain saved.
Keyboard display or board
defective.
Contact TITAN service dept.
Following the welding
cycle the tool cannot be
detached from the strap,
lever 3
(blocking/loosening) must
be actuated with
enormous force being
applied.
Detension unit is not released /
deblocked.
Slightly pull lever 3
(79)
(do not
pull it completely) and check
whether the non-return unit is
deblocked. Contact TITAN
service dept.
Detension unit is blocked by
something or it is damaged.
Check if foreign objects are found
in the detension unit or if visible
damage can be detected.
Contact TITAN service dept.
Reduction gear unit damaged.
Check if the reduction gear unit
can be turned easily and evenly.
H TA 220 EU 06/10