202
Genie Distribution User Manual v1.6
© Tieline Pty. Ltd. 2015
Read-Write access. The R/O Community identifier allows Read Only
level access.
R/W Community
The R/W Community identifier allows Read/Write level access.
Configuring SNMP Settings in the Codec
1. Open the Java Toolbox Web-GUI and click the
Settings
symbol at the top of the screen to
display the
Settings panel
.
2. Click the
Options
button at the top of the
Settings panel
.
3. Click in the text boxes to enter SNMP configuration settings.
4. Click the
Save Settings
button to save the new settings.
MIB Files for SNMP Configuration
Management Information Base (MIB) files are required for SNMP applications to interact with your
Tieline codec and interpret SNMP data. The codec supports SNMPv1 and SNMPv2 MIB protocols.
The required MIB files can be downloaded from the codec using the following link in a PC web
browser connected to the same network as your codec:
·
http://<YOUR_CODEC_ADDRESS>/mibs/tieline-mibs.zip
Save the .zip file to your PC and import the contents into the MIB browser you use to manage
SNMP-enabled network devices.
Important Note:
The codec supports the attributes specified in the MIB-II standard.
Please verify that your SNMP software contains the required files as specified in
RFC
1213
.
24.25
Download Logs
The codec is capable of providing diagnostic information via user logs, which can either be sent to
Tieline support, or downloaded for user diagnostics.
Procedure for Sending Logs to Tieline
1. Open the Java Toolbox Web-GUI and click the
Help
symbol at the top of the screen to
display the
Help panel
.