THUNDER LASER
MINI-60
www.thunderlaser.com
DONGGUAN THUNDER LASER EQUIPMENT CO.,LTD
Tel :(86)769 82665376
36
expired. Each relay has a freely adjustable delay time from 1-300 seconds.
Set up delay time:
Enter “Menu” switch once. The red LED will blink and the display will show you the delay
time in second for the first relay. A yellow LED close to the active relay will show you.
Which one is active.
The display does show the delay time in seconds. By
pressing “down” or “up” you can
change the value. By holding a switch down for more than 2 seconds the value will
increase or decrease automatically.
By pressing “Menu” you can switch to relay number 2 now and set the delay time for this
one.
For changing delay values for 3
rd
and 4
rd
relay you have to press “Menu” again.
When 4
th
relay is active and you press “Menu” again. The TL-Timer will turn back to
normal operating mode; the red LED will stop blinking.
After turning of power the TL-Timer will remember the delay-time-values, you did enter
before.
Relay-Output:
Each of the 4 relays offers a opening and closing switch with current capacity of max.
8Amps and a power capacity of max. 1000W.
Higher loads must be controlled by using a power contactor.
About TL-Timer controller interface and buttons description
:
1
:
Interface 1
,
connection warning light
,
delay time is set to 1 second
(
Factory default
settings, the user can be set if required
)
2
:
Interface 2
,
connection air pump
,
delay time is set to 5 second
(
Factory default settings,
the user can be set if required
)
3
:
Interface 3
,
connection exhaust fan
,
delay time is set to 5 second
(
Factory default