background image

INSTALLATION MANUAL

SAILOR 6110 GMDSS System

Summary of Contents for SAILOR 6110

Page 1: ...INSTALLATION MANUAL SAILOR 6110 GMDSS System...

Page 2: ......

Page 3: ...SAILOR 6110 GMDSS System Installation manual Document number 98 130752 A Release date December 22 2010...

Page 4: ...rane is not responsible for the content or accuracy of any translations or reproductions in whole or in part of this manual from any other source Copyright 2010 Thrane Thrane A S All rights reserved T...

Page 5: ...wave radiation hazards During transmission the antenna in this system radiates Microwave Power This radiation may be hazardous to humans close to the antenna When the system is powered make sure that...

Page 6: ...se the system For information on usage refer to the user manual Part numbers for related manuals are listed in the next section This manual has the following chapters Introduction contains an overview...

Page 7: ...DSS System User manual 98 130753 2 SAILOR 6006 and 6007 Message Terminal Installation manual 98 130088 3 SAILOR 6101 and 6103 Alarm Panel Installation and user manual 98 130981 4 SAILOR 6081 PSU and C...

Page 8: ...ouch the antenna To indicate what the user should select in the user interface Example Select SETTINGS LAN Italic is used to emphasize the paragraph title in cross references Example For further infor...

Page 9: ...01 6103 Alarm Panel 7 1 8 SSA option 8 Chapter 2 Unpacking and activation 2 1 Initial inspection 9 2 2 Registering your SAILOR 3027 10 Chapter 3 Installing the system 3 1 General installation requirem...

Page 10: ...sting the system 49 5 3 Generating a diagnostic report 55 Chapter 6 Maintenance 6 1 Maintenance guidelines 57 6 2 Repacking for shipment 58 6 3 Available parts 59 App A Technical specifications A 1 SA...

Page 11: ...system and briefly describes each unit in the system It has the following sections SAILOR 6110 system overview SAILOR 3027 GMDSS Terminal SAILOR 6006 Message Terminal SAILOR 6081 PSU and Charger SAIL...

Page 12: ...ssages and distress alerts through the Inmarsat C satellite network Each unit is briefly described in the following sections For a description of the services supported by the Inmarsat C system and th...

Page 13: ...no user serviceable parts The SAILOR 3027 is very compact and is designed to operate in extreme weather conditions It has a highly sensitive built in GPS module with 50 channels Galileo ready The ante...

Page 14: ...ge the configuration and test the system The SAILOR 6006 has a Distress button for sending distress alerts The SAILOR 6006 has a touch screen interface and can be operated without a keyboard However a...

Page 15: ...6081 PSU and Charger provides automatic switch over to a connected backup battery if 115 230 VAC is not available It also has a charger function for charging the battery when 115 230 VAC is available...

Page 16: ...USB connectors on the SAILOR 6006 In the SAILOR 6110 system it is primarily used to print SafetyNet EGCs with Distress priority 1 6 SAILOR 6197 Ethernet switch The Ethernet switch connects the system...

Page 17: ...as one Distress button used for remote initiation of distress alert transmissions and for indication of incoming distress and urgency messages on Inmarsat C GMDSS systems SAILOR 6103 Multi Alarm Panel...

Page 18: ...It connects to the SAILOR 6110 system through the THRANE 6194 Terminal Control Unit The CAN interface which connects the SAILOR 6110 system to the THRANE 6194 also provides the power for the SSA opti...

Page 19: ...terial for future use Check that the contents of the shipment are as listed in the enclosed packing list If the contents are incomplete if there is mechanical damage or defect or if the system compone...

Page 20: ...ed at either a PSA company or directly to the ISP A PSA is a company handling the activation of Inmarsat mobiles and is short for Point of Service Activation ISP is the company that provides the Inmar...

Page 21: ...rranged payment of calls for this MES through tick one a Accounting Authority AA b Inmarsat Service Provider ISP Enter ISP or AA Code If the Code is unknown enter the name of the ISP or AA NOTE If the...

Page 22: ...mobile number must be entered in the SAILOR 3027 using the SAILOR 6006 Message Terminal To enter the mobile number in the SAILOR 3027 do as follows 1 In the Message Terminal display select Network 2...

Page 23: ...stem on page 27 For information how to configure the system see the user manual 1 The following sections describe General installation requirements Mounting the SAILOR 3027 Mounting the SAILOR 1252 pr...

Page 24: ...curs in the Mains supply Power consumption The total power consumption varies primarily due to system activities Make sure the backup battery is capable of providing the required power As a guideline...

Page 25: ...n as close as possible to the SAILOR 6081 for connecting the units to ship ground hull SAILOR 1252 Printer 3 W 30 W Unit Idle power Max power Note Only units with a replaceable fuse are listed in the...

Page 26: ...Place the terminal so that no person can accidently get closer to the terminal than the safety distance 1 ft 0 3 meters Distance to exhaust fumes Do not place the terminal close to the funnel directl...

Page 27: ...on covers no more than 2 of the view from the terminal To obtain this the distance between the obstruction and the terminal must be minimum 29 x diameter of the obstruction Example The obstruction is...

Page 28: ...o a proper ground i e the ship s structure hull This is very important in order to protect persons and equipment from lightning and safely bypass interference from Radar VHF MF HF radio equipment and...

Page 29: ...minal 3 Mount the adapter on the terminal using screws 4 Tighten the adapter to the pole You may use the adjustable pole railing mount as an alternative to the pole mount See the next section for deta...

Page 30: ...1 poles and can be mounted on a vertical or horizontal pole Do as follows 1 Attach the pole railing mount to the pole using the included nuts and spacers The drawing below and on the next page show t...

Page 31: ...Chapter 3 Installing the system Mounting the SAILOR 3027 21 3333 Installing the system Horizontal pole...

Page 32: ...Chapter 3 Installing the system 22 Mounting the SAILOR 3027 Mechanical outline drawing SAILOR 3027 GMDSS Terminal 170 5 164 6 M4 x 3 Length of thread 6 mm 120 157 145 Connector housing custom made 64...

Page 33: ...printer The printer must be placed indoors in a dry location close to the SAILOR 6006 Message Terminal The Message Terminal and the printer are connected with a USB cable which means the maximum dista...

Page 34: ...nter To mount the SAILOR 1252 with the included mounting kit H1250 do as follows 1 Fasten the plate to the printer with the 3 M4 x 20 screws included in the kit 2 Fasten the plate with printer to the...

Page 35: ...Chapter 3 Installing the system Mounting the SAILOR 1252 printer 25 3333 Installing the system Mechanical outline drawing SAILOR 1252 Printer...

Page 36: ...Chapter 3 Installing the system 26 Mounting the SAILOR 1252 printer...

Page 37: ...ing sections Connecting the units Grounding the units The CAN backbone Connecting power Connectors and pin out 4 1 Connecting the units Before connecting the units read all sections in this chapter Co...

Page 38: ...erminal SAILOR 6101 6103 Alarm Panel CAN CAN bus CAN X5 SAILOR 1252 Printer DC input PWR LAN LAN USB USB Mains 150 230 V AC MAINS AC L MAINS AC N Backup battery 24 V DC X2 BATTERY X2 BATTERY Ship grou...

Page 39: ...000 Micro Device Cable Included 6 m with SAILOR 6110 W3 NMEA 2000 Mini Device Cable Included 6 m with SAILOR 6110 W4 W5 W6 Power cables to Message Terminal Alarm Panel and printer Included with each u...

Page 40: ...t including cable SAILOR 6100 913 SSA Kit or SAILOR 6100 916 SSA US Kit For a list of additional cables and connectors available from Thrane Thrane see Available parts on page 59 C1 Mini Micro NMEA 20...

Page 41: ...power supply Using a T connector this cable can be connected to the full CAN bus and thus to the SAILOR 3027 terminal On the SAILOR 6081 PSU and Charger connect the following wires from the CAN cable...

Page 42: ...rger For further information on how to install the SAILOR 6081 PSU and Charger see the installation manual for the power supply 4 Ground plane connected to ship hull Ground stud Important When install...

Page 43: ...ation resistance or inside the last device on the CAN backbone The cable length from each device to the CAN T connector must be maximum 6 m The total length of the backbone must be maximum 200 m The d...

Page 44: ...als 4 4 2 Calculating power cables for the SAILOR 3027 The SAILOR 3027 GMDSS Terminal has one CAN connector which is also used for power input If possible use the cables included with your SAILOR 6110...

Page 45: ...lation the cable impedance of the supplied power cables including the impedance in the joint of the two cables In the following example the measured source impedance includes the impedance of the supp...

Page 46: ...ter from step 2 The length is multiplied by 0 5 above because there are two conductors in the cable Example Ship supply voltage 15 V DC Ship source impedance measured 50 m Extension cable type 1 31 mm...

Page 47: ...t of the Mini Micro T connector 3 Connect the cable for the GMDSS Terminal to the T connector but do not connect the other end to the terminal 4 At the unconnected end of the CAN cable measure the sou...

Page 48: ...nnecting to power as well as communication interfaces The table and drawing below show the pin out for the connector Important Secure the CAN cable at the terminal to avoid stressing the CAN connector...

Page 49: ...R 1252 Printer and to the keyboard Ethernet interface Connects to the SAILOR 6197 Ethernet Switch ground stud Connects to ship ground CAN interface Connects to the GMDSS Terminal and optionally other...

Page 50: ...ents Ethernet The figure and table below show the connector outline and pin assignments Pin number Pin function Wire color 1 5 V Red 2 D White 3 D Green 4 GND Black USB Type A socket Pin number Pin fu...

Page 51: ...nnector outline and pin assignments X4 Power input The figure and table below show the connector outline and pin assignments Pin number Pin function Wire color 1 Not connected None 2 CAN_S Red 3 CAN_C...

Page 52: ...rm Panel which has 3 Distress buttons one for each system Both alarm panels have the following connectors DC input Connects to the SAILOR 6081 PSU and Charger Ethernet interface Connects to the SAILOR...

Page 53: ...Ethernet interface The figure and table below show the connector outline and pin assignments Pin number Pin function 1 DC 2 DC 3 ON_IN 4 NC Panel lock 4 pin male Pin number Pin function Wire color 1...

Page 54: ...Charger The SAILOR 6081 PSU and Charger has a number of spring terminals In the SAILOR 6110 system connect the spring terminals as follows MAINS AC Connects to Mains 150 230 V AC X2 15 V output Conne...

Page 55: ...ing interfaces on the SAILOR 1252 Printer are used in the SAILOR 6110 system USB Type A connector Connects to the USB interface in the SAILOR 6006 Message Terminal DC input connector Connects to the S...

Page 56: ...ter 4 Connecting the system 46 Connectors and pin out Spring terminals X7 to X14 Connect to the SSA buttons if installed For further information see the Installation and user manual for the THRANE 619...

Page 57: ...nerating a diagnostic report 5 1 Installation check list After installing the SAILOR 6110 system you can use the following check list to make sure you have installed the system correctly Important Mak...

Page 58: ...cable from Message Terminal to printer Wiring overview on page 28 Ethernet cables Do all cables meet the requirements in this manual Power cables Connectors and pin out on page 38 CAN cables USB cabl...

Page 59: ...ged on If the system is not ready the status field may show one of the following The GMDSS Terminal is logged out of the Inmarsat C network but is synchronized with the satellite The GMDSS Terminal is...

Page 60: ...king a Distress button test The SAILOR 6006 Message Terminal has a test function that allows test of the Inmarsat C Distress Buttons Distress LEDs and wiring To test the Inmarsat C Distress buttons in...

Page 61: ...ant Before pressing any Distress buttons make sure the display of the SAILOR 6006 shows Test in progress Otherwise you may accidently send a real Distress alert Note Before pressing any Distress butto...

Page 62: ...the Distress buttons should work the same way as in a real Distress situation For details on the Distress buttons see the user manual for the SAILOR 6110 GMDSS System 1 5 When you have finished testi...

Page 63: ...t indicators and alarm buttons are flashing 2 While holding the Test button press any other button on the Alarm Panel including the Distress button The buzzer sounds to indicate that the pressed butto...

Page 64: ...e Message Terminal do as follows 1 In the Message Terminal display select Network 2 Select Status 3 Select Link test The Link test window shows the result of the latest link test if any 4 Select Perfo...

Page 65: ...rking properly a diagnostic report may help service personnel troubleshooting the system To generate a diagnostic report do as follows 1 Select System 2 Select Advanced at the bottom of the page 3 Sel...

Page 66: ...Chapter 5 Installation check and test 56 Generating a diagnostic report...

Page 67: ...keep the correct time when power is disconnected The clock battery in the SAILOR 6006 Message Terminal must be replaced by qualified personnel 6 1 1 Handling precautions for SAILOR 3027 Do not expose...

Page 68: ...return address model number and full serial number Mark the carton FRAGILE to ensure careful handling If the original shipping carton is not available the following general instructions should be used...

Page 69: ...icro NMEA 2000 T connector 406100 932 Inline Micro termination Connector 406100 933 Male Mini NMEA 2000 Field Connector 406100 934 Male Micro NMEA 2000 Field Connector 406100 940 6 m NMEA 2000 Micro D...

Page 70: ...Chapter 6 Maintenance 60 Available parts 6 3 2 Adjustable pole railing mount kit Part number Item 403027 103 Adjustable pole railing mount kit for SAILOR 3027...

Page 71: ...ons for the SAILOR 6110 GMDSS System and the SAILOR 3027 GMDSS Terminal For specifications on the other units in the GMDSS System refer to the installation manuals for the individual units A 1 SAILOR...

Page 72: ...e elevation EIRP Min EIRP 7 dBW at 5 degrees elevation Inmarsat Protocol services Message transmission and reception with IA 5 ITA 2 and binary transfer to from Telex PSTN telephone modems and fax mod...

Page 73: ...ale Power input 9 V 32 V DC from CAN compliant power supply 15 V DC Nominal Input Power Max Power 30 W Max continuous current 2 8 A Max peak current 4 A startup Standby power Rx mode 2 W Sleep Mode po...

Page 74: ...survival Up to 25 mm Velocity Max velocity up to 140 km hour 87 mph Wind Wind speed up to 200 km hour 124 mph Vibrations operational Random 5 20 Hz 0 005 g2 Hz 20 150 Hz 3dB oct 0 5g RMS Vibrations su...

Page 75: ...s Safety System GMDSS consists of several systems some of which are new but many of which have been in operation for many years The system is intended to perform the following functions alerting inclu...

Page 76: ...marsat s satellite networks ISP Inmarsat Service Provider The company providing the Inmarsat services L LAN Local Area Network A computer network covering a small physical area like a home office scho...

Page 77: ...t of Service Activation A company handling the activation of Inmarsat mobiles S SARF Service Activation Registration Form SSA Ship Security Alert U USB Universal Serial Bus A specification to establis...

Page 78: ...Glossary 68...

Page 79: ...6081 44 SAILOR 6101 6103 42 D diagnostic report 55 distance compass 16 safety 16 to other equipment 16 document number this manual i documents related v F fuses 15 G GMDSS terminal connector and pin...

Page 80: ...y distance SAILOR 3027 16 safety summary iii SAILOR 1252 description 6 mounting 23 SAILOR 3027 connector and pin out 38 description 3 mounting on flat surface 22 mounting on pole 19 placing 16 specifi...

Page 81: ......

Page 82: ...98 130752 A Thrane Thrane A S info thrane com www thrane com...

Reviews: