BASIC TROUBLESHOOTING
58
MANUAL 430429-490
5.0 BASIC TROUBLESHOOTING
5.03 Error Code List
When you need a service and the following steps do not solve the problem, please call 1-
(937)-440-0100 for assistance.
Table 6. Error Code
E01 Temp NG
Thermal shutdown
Allow the unit to cool for
five minutes before turning
the power supply ON.
E02 Thermal NG
Thermal shutdown
Allow the unit to cool for
five minutes before turning
the power supply ON.
E03 OCR1
Primary Over
Current
Reapply the power.
E04 Output OVR
Output Over Voltage Reapply the power.
E05 Output OCR
Output Over Current Reapply the power.
E11 AC OVR1
Input Over Voltage
Apply correct input voltage.
E12 AC OVR2
Input Over Voltage
Apply correct input voltage.
E13 AC UVR1
Input Under Voltage Apply correct input voltage.
E14 AC UVR2
Input Under Voltage Apply correct input voltage.
E21 DC OVR1
Input Over Voltage
Apply correct input voltage.
E22 DC UVR1
Input Over Voltage
Apply correct input voltage.
E23 DC OVR2
Input Under Voltage Apply correct input voltage.
E24 DC UVR2
Input Under Voltage Apply correct input voltage.
E25 DC UnBalance
Voltage Unbalance
Reapply the power.
E81 Link NG
Link Error
Verify primary source voltage
and set INPUT SELECT switch
to correct setting.
E82 Link Sw Wrong
Link Circuit Error
Needs service / repair.
E83 Link TimeOut
Link Circuit Error
Needs service / repair.
E84 PreCharge NG
Pre Charge Error
Needs service / repair.
E85 PreCharge
TimeOut
Pre Charge Error
Needs service / repair.
E91 EEPROM NG
Panel Unit Error
Needs service / repair.
E92 Panel Fail
Sensor Unit Error
Needs service / repair.
E93 Sensor Fail
EEPROM Error
Needs service / repair.
E94 TempSensor Open Thermal sensor TH1
open
Needs service / repair.
E99 Control NG
Control Unit Error
Needs service / repair.