MANUAL 430429-490
53
SAVE/LOAD OPERATION
Parameters that are not accessed during a SAVE/LOAD
operation.
1)
Weld mode.
The weld mode is not saved. The operator, after a LOAD,
must press the ‘PROCESS KEY’ (5) until the desired weld
mode is displayed in the ‘MODE LED’ (4).
2)
Voltage or Current value.
Voltage or current values are not saved. The voltage or
current setting is dependant on the A/V control (1) or a
remote device, if used.
3)
Contactor On/Off
The contactor On/Off condition prior to a SAVE operation is
not saved. When a program is LOADed, the contactor will
automatically be set in the OFF condition.
Automatic SAVE/LOAD when the power switch is turned
off/on .
When the unit is turned off it will automatically save all the
parameters for all the welding modes at the time of turn off.
When the unit is then turned on, all welding parameters at
the time of turn off will be loaded. The unit will not
automatically save the current welding parameters if the unit
was turned off while there was welding current.