![Thermal Arc 400MSTW CC Operating Manual Download Page 33](http://html1.mh-extra.com/html/thermal-arc/400mstw-cc/400mstw-cc_operating-manual_1103167033.webp)
MANUAL 430429-490
33
SAVE/LOAD OPERATION
9. Turn on shielding gas.
10. Wear welding helmet with proper filter lens according to ANSI Z49.1.
11. Place the PRIMARY POWER switch (18) to ON.
12. After power on, push “PROCESS” button and set to “STK” mode.
13. Following the “LIFT TIG Mode Operation Diagram”, set each kind of
welding parameter.
14. Activate remote control device.
In LIFT TIG mode, touch electrode to work and lift to start arc.
When it is short-circuit, the output current is fixed 15A.
15. Begin welding.
WARNING
HIGH CONCENTRATION OF SHIELDING GAS can impair health or kill.
Shut off gas supply when not in use.
Modifiable Parameters
1)
Contactor
Selects whether the welding current is ON/OFF.
Remote (Default)
Current controlled by a remote switch
ON
Current available
2)
A/V
Set the desired welding current with the ‘Amperage/Voltage
control’ (1) or with a remote device.
PANEL (Default)
A/V set with ‘Amperage/voltage control’
REMOTE
A/V set with a remote device
3)
Pulser
Sets pulse output ON/OFF.
OFF (Default)
Pulse output OFF, DC output
ON
Pulse output ON