OPERATOR CONTROLS
18
MANUAL 430429-490
Input Power
Each unit incorporates an INRUSH circuit and input voltage sensing circuit.
When the MAIN CIRCUIT BREAKER is turned on, the inrush circuit
provides a pre-charging of the input capacitors. SCR's in the Power Control
Assembly (PCA) will turn on after the input capacitors have charged to full
operating voltage (after approximately 5 seconds).
NOTE
Note the available input power. Damage to the PCA could occur if 575VAC
is applied with the INPUT SELECT switch in the 208-230V position.
208VAC 50/60Hz three-phase /single-phase
230VAC 50/60Hz three-phase /single-phase
400VAC 50/60Hz three-phase
460VAC 50/60Hz three-phase
575VAC 50/60Hz three-phase