MANUAL 430429-490
39
SAVE/LOAD OPERATION
4)
Pulse Freq.
Sets the desired pulse frequency. This parameter is only
displayed and available for modification when the ‘Pulser’
parameter listed previously is set to ON.
Selectable from 0.5Hz to 500Hz (Default 100Hz)
5)
Pulse Width
Sets the desired pulse width of the peak current. This
parameter is only displayed and available for modification
when the ‘Pulser’ parameter listed previously is set to ON.
Selectable from 15% to 80% (Default 50%)
6)
Back Cur.
Sets the desired base current of the pulse output. This
parameter is only displayed and available for modification
when the ‘Pulser’ parameter listed previously is set to ON.
Selectable from 0% to 100% (Default 30%)
7)
Sloper
Sets Sloper output ON/OFF.
OFF(Default)
Sloper mode OFF
ON
Sloper mode ON
8)
Init Cur.
Sets the desired initial current. This parameter is only
displayed and available for modification when the ‘Sloper’
parameter listed previously is set to ON.
Selectable from 0% to 100% (Default 30%)
9)
Final Cur.
Sets the desired final current. This parameter is only
displayed and available for modification when the ‘Sloper’
parameter listed previously is set to ON.
Selectable from 0% to 100% (Default 30%)