RES-12XR3-S for X8DAL-3/i Installation Manual
Version 1.0
1-2
Themis Computer
The RES-12XR3-S for X8DAL-3/i is designed within a 1RU-high (1.75”) form-factor
17” (43.2 cm) deep and 17” (43.2 cm) wide (which, with mounting brackets, fits a 19”-
wide rack). Major features of the RES-12XR3-S for X8DAL-3/i motherboard are
listed in
Table 1-2
.
Table 1-1.
RES-12XR3-S for X8DAL-3/i Motherboard Options
Mother-
board
a
IPMI
SATA
SAS
Memory
Slots
Graphics
Audio
PCI-e Slots
PCI
33MH
z
PCI-e
2.0
x4
PCI-e
2.0
x16
PCI-e
x4
X8DAL-3
No
Yes
Yes
6
Yes
Yes
1
b
1
1
2
X8DAL-i
No
Yes
No
6
Yes
Yes
1
b
1
1
2
a—SuperMicro Computer, Inc.
b—1 in x16 slot.
Table 1-2.
RES-12XR3-S for X8DAL-3/i Major Features
Processors
Two Quad Core Intel® 5600/5500 Series Xeon Processors
Chipset
Intel® 5500 (Tylersburg) chipset
2x IOH-24D
Memory
6 240-pin DIMM sockets
Up to 48 GB of total memory
1333/1066/800-MHz DDR3 ECC-Registered Memory Modules
Peripheral Support
Eight SAS ports from the motherboard (X8DAL-3 only)
(RAID 0, 1, 5, 10 support—Windows; RAID 0, 1, 10 support—Linux)
Six SATA ports/six SATA storage drives supported
1
combination
CD-RW/DVD-ROM slimline drive
Expansion slots
See
Table 1-1
for details
Rear-Panel I/O
See
Table 1-4
on page 1-8 for details
Operating temperature
a
0° up to 65° C (32° up to 149°F)
Shock endurance
a
35G @ 25-msec duration (3 axis)
Dimensions
1.75” (1RU) high, 17” (43.2 cm) wide (19”/48.3 cm with mounting brackets),
17” (43.2 cm) deep
Rack-mount brackets
and slides
Left and right rack-mount tabs are attached to the chassis
Left and right rack-mount slides are
optional
Dual power supplies
750 watts each, auto-ranging (100–265 VAC)
Load-sharing N+1 redundant, hot-pluggable
(
Optional
)—Choice of 750-watt (48V) or 500-watt (28V) DC Power supply
a—Specifications are dependent on the configuration specified in this manual.
Summary of Contents for RES-12XR3-S
Page 5: ...iii Themis Computer VersionRevisionHistory Version 1 0 November 2010...
Page 16: ...RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 xiv Themis Computer...
Page 20: ...RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 xviii Themis Computer...
Page 64: ...RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 2 20 Themis Computer...
Page 99: ...BIOS Setup Utility BIOS Error Beep Codes 3 35 Themis Computer...
Page 100: ...3 36 Themis Computer RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0...
Page 108: ...Themis Computer RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0 B 4...
Page 132: ...E 4 Themis Computer RES 12XR3 S for X8DAL 3 i Installation Manual Version 1 0...