PROVIDENCE INSERT
PELLET STOVE
14
Note: Above installation examples are for reference. All installation must follow local codes and requirements.
Additional Venting
Your Thelin PROVIDENCE Insert is equipped with a blocked flue/high temp safety sensor that will shut the
stove off if there is a down draft, blocked flue, or high temperature condition.
If you install the stove on the side of the house that is hit by prevailing winds (usually 30 to 40 mph or greater)
there is a chance that the sensor will be activated and the stove will shut off. The solution to this problem is to
run the pipe up vertically through the eave and use a high wind cap on the vertical termination.
Outside Air Hook-Up
Make sure a rodent guard is used after penetrating the outside wall. Source a wall thimble with a built-in outside
air hook-up and rodent guard screen.
3C- Horizontal vent without outside air
3D- Horizontal vent with outside air
Summary of Contents for providence
Page 6: ...PROVIDENCE INSERT PELLET STOVE 6 LABORATORY LISTING LABEL...
Page 8: ...PROVIDENCE INSERT PELLET STOVE 8 FIGURE 1 STOVE DIMENSIONS...
Page 19: ...PROVIDENCE INSERT PELLET STOVE 19 FIGURE 8 ADJUSTABLE HOPPER ASSEMBLY...
Page 20: ...PROVIDENCE INSERT PELLET STOVE 20 FIGURE 9 CONTROL PANEL...
Page 31: ...PROVIDENCE INSERT PELLET STOVE 31 FIGURE 13 CLEAN OUT COVERS FIGURE 14 CLEAN OUT VENT PORT...
Page 32: ...PROVIDENCE INSERT PELLET STOVE 32 FIGURE 15 COMBUSTION FAN...
Page 37: ...PROVIDENCE INSERT PELLET STOVE 37 FIGURE 18 ELECTRICAL SCHEMATIC WIRING DIAGRAM...
Page 40: ...PROVIDENCE INSERT PELLET STOVE THELIN HEARTH PRODUCTS 63 Laxalt Dr Carson City NV 89706...
Page 41: ......