DVOR 432
Operation and Maintenance
Installation
2-17
Ed. 01.04
2.5
INSTALLATION AT THE RACK IN THE SHELTER
2.5.1
General
This chapter describes the connections at the transmitter and ASU rack: power supply, RF connecĆ
tions, interface connections and connection of a Remote Control (RMMC).
NOTE:
For the Thales ATM shelter delivered with the navaids systemall fuses are preinstalled.
If the shelter is provided by the customer, he will be responsible for the installation includĆ
ing a mains fuse box with arrester and a battery fuse box. Following fuse protection is
recommended: external mains fuse for transmitter cabinet F= C20A, for battery fuse
F1= K50A (power) and F2= G0.2A (sensor lines), regard also Fig. 2-6.
For a mains voltage of 115 VAC the standard mains wiring concept allows up to 3 ACC
modules. For a 115 VAC supply with 4 modules provided, standard mains wiring has to
be adapted concerning diameter of supply cables, size of mains terminals and mains filter.
2.5.2
Power Supply
2.5.2.1
Power Connections
See Fig. 2-23, 2-24.
The BCPS modules are located in the ASU (100 W version) or in the transmitter cabinet (50 W version).
The terminal blocks for electrical and signal connections as listed below are installed on the BCPS
connection plate and the C-bar, which are located at the lower back side of the ASU or transmitter
cabinet, or on the ASU or transmitter cabinet bottom plate. They are accessible after opening the rear
door of the rack. The connections at the transmitter cabinet in the 100 W version are made to the C-
bar at the lower back side.
ASU cabinet, rear (100 W version only) or DVOR cabinet, rear (50 W version only):
BCPS connection plate:
- 6 mains terminals L1, L2, L3, N, PE (Protective Earth) and FPE (Functional Protective Earth)
- 1 Speedy connector 26-pin for control signals to/fromthe BCPS fromTX
- 2 single terminal blocks for battery (+ and -), factory wired
- 2 single terminal blocks for NAV equipment, factory wired
- 5 terminals for measuring lines to the battery, factory wired
C-bar:
- 2 single terminal blocks for connecting the battery (+B,-B)
- 5 terminals (2,1, F, F, 0) for measuring lines to the battery BAT2, BAT1, 2 BFUSE and BAT0
- 1 terminal block (+A,-A) for connecting the ASU power supply
- 4 terminals (+D,-D; +R,-R) for connecting collocated DME and Radio Link (RL) equipment
- 1 single terminal block (+N,-N) for connecting the NAV equipment, factory wired
Bottomplate:
- 5 mains terminals L1, L2, L3, N, PE
- mains filter with mains terminals 4 In/4 Out/1 PE (European version only)
DVOR cabinet, rear (100 W version only):
C-bar:
- 1 terminal block (+N,-N) for connecting the NAV equipment, factory wired
- 1 terminal block (+A,-A) for connecting the ASU power supply
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...