supplied with battery
DVOR 432
Operation and Maintenance
Maintenance
5-7
Ed. 01.04
5.4
STARTUP, CARE AND MAINTENANCE OF THE LEAD BATTERY
5.4.1
Startup Specifications for the Lead Battery in Navigation Installations
5.4.1.1
General
For countries in Europe, the sets of lead batteries in the navigation installations are normally supplied
already filled and charged by the manufacturer. On site the batteries then merely need to be installed
and connected to the power supply unit of the navigation installation. Batteries supplied in a non-
filled state to their point of installation must be set up, filled and charged there in accordance with the
manufacturers handling specifications. The batteries can be supplied non-filled in either a dry pre-
charged state, or a non pre-charged state (see 5.4.1.3.2 and 5.4.1.3.3 ). The battery may not be
removed from its transport packing until immediately prior to startup.
CAUTION
Maintenance-free batteries have to be set into operation within half a year after delivery
to prevent drawback in the battery lifetime.
The startup procedure comprises the following stages:
a) Installation on site, interconnection of the cells with the cell connectors and connection to the
electrical installation;
b) Filling with accumulator acid;
c) Immediate subsequent charging or activation of the plates (see 5.4.1.3)
d) Immediate subsequent activation in standby parallel mode.
These instructions do not cover the installation work, but instead deal merely with filling and activation
using tools which, even in remote areas, are either available or easily obtainable. They moreover apĆ
ply only to batteries for which a rated acid density of 1.24 kg/l is specified by the manufacturer, e.g.
Gro E, iron-clad and block batteries, and not to starter batteries or batteries with a fixed electrolyte.
The aids required are as follows:
Accumulator acid
The acid must have a particular density. If this value is incorrect, the mixture
should be made up of high-density sulphuric acid and specially purified waĆ
ter (see 5.4.1.2.2 ).
1 Acid syringe with areometer
1 Thermometer
1 Acid jug (non-metallic)
1 Funnel (non-metallic)
- Float acid level indicator
- Handling specifications
- Battery-charging power supply (BCPS), type FRAKO
- Various resistors
- Single-wire cables (2.5... 6 mm
@
)
- Ammeter and voltmeter (accuracy <1 %)
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...