Menu/
INSTRUCTION
C: Commands
A: Activities
Submenu
DVOR 432
Alignment Procedure
Operation and Maintenance
Annex Nextfield
AN-24
Ed. 01.04
4.6.2
Setting of TX2 with Monitor 1
a) Switch on TX2.
C
Switch TX2 On
b) Switch over to TX2
C
Set TX2 Aerial
Set TX2 in the same way as described for TX1 in 4.6.1. Continue to use
A/TS
TX settings
monitor 1 for monitor indications. Therefore omit 4.6.1.2 b) (do not
change the AGC value of monitor 1 again), but checkthat the RF level
indication is 100
±
5 %. Use activity maskA/TS 'TX Settings'.
4.6.3
Setting and Check of Monitor2
4.6.3.1
Monitor 2 with TX1 on Aerial
NOTE: TX1 radiating.
Switch on TX1.
C
Switch TX1 On
Switch over to TX1
C
Set TX1 Aerial
a)
RF level
Set 'M2 AGC Adjustment' value to 'M2 RF Level' indication of 100 %.
A/MC
M2 AGC Adjustment
--,- %
If necessary, change 'M2 Digital.Ctrl.Attenuation'.
-- dB
b)
30 Hz AM mod. depth
A/MC
M2āMod.Depth
Checkthe 'M2 Mod. Depth 30 Hz AM' reading.
ā30Hz AM
NOTE:
Use window 'MON2 Measurement. Nominal value: 30.0 ±1.0 %
c)
Subcarrier
A/MC
Mon 2 Measurement
ca) Checkthe 'M2 Mod. Depth 9960 Hz AM' reading.
NOTE:
Use window 'MON2 Measurement. Nominal value: 30.0
±
1.0 %
cb) Checkthe 'M2 Mod. Index 30 Hz FM' reading.
NOTE:
Use window 'MON2 Measurement. Nominal value: 16.0
±
0.5 %
d)
Azimuth
A/MC
Mon 2 Measurement
Checkthe 'M2 Azimuth' reading.
NOTE:
Use window 'MON2 Measurement. Nominal value: same as in
4.6.1.6b),
±
0.2
4.6.3.2
Monitor 2 with TX2 on Aerial
NOTE:
TX2 radiating.
Switch over to TX2
C
Set TX2 Aerial
Checkfollowing monitor 2 indications:
a) RF level.
A/MC
M2 RF-Level
NOTE:
Nominal value: 100 ±5 %
.
b) 30 Hz AM mod. depth.
A/MC
M2 Mod. Depth 30Hz
AM
NOTE:
Nominal value: 30.0
±
1.0 %.
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...