DVOR 432
Operation and Maintenance
Alignment Procedure
Annex Nextfield
AN-13
Ed. 01.04
4.2.6
Special Notes to DVOR with Nextfield Monitor
4.2.6.1
Switching On and Setting of DVOR with Nextfield Monitor
The nextfield monitor monitors the radiated DVOR-signal from its position at the edge of the counterĆ
poise. The signal however is not equivalent to the farfield and is not suitable for phasing of the installaĆ
tion. The 9960 Hz modulation depth is determined from two signals with an individual AGC each. It
can be set correctly only in the monitor if it is correctly in the signal in space.
During first alignment it is therefore recommended to phase the installation with the monitor signal
of a mobile or fixed field dipole. Here, the modulation depth of the 9960 Hz is also to be set. After this
alignment the mobile field dipole can be dismantled. The fine adjustment of the 9960 Hz modulation
depth is performed during flight check. If due to the geographical position of the DVOR installation,
e.g. on a mountain, a normal field dipole cannot be installed the phasing and setting of the 9960 Hz
modulation depth is performed during flight checkonly.
NOTE:
The carrier antenna has very carefully to be adjusted for a good RF matching. A directional
coupler is inserted in the RF line to the carrier antenna, which couples out the sideband
signals, USB and LSB, which are received from the sideband antennas, and supplies it
to the subassembly Monitor (MSP-D). The interference signal reflected by the carrier anĆ
tenna is about 20 to 30 dB greater than the received wanted signal. The worse the matĆ
ching of the antenna the more unfavorable is the signal to noise ratio and the inaccurate
are the monitor measurement values. Possibly it is indicated only less than 30 % of the
9960 Hz modulation depth due to a bad matching of the antennas, especially of the midĆ
dle antenna.
The monitor program used for nextfield monitoring processes both signals of the nextfield dipole and
of the conventional field dipole. Therefore the following procedure is recommended:
1. Adjustment of the installation with conventional farfield monitor (fixed or mobile).
2. Adjustment with nextfield monitor
4.2.6.2
Setup of the Installation with Field Dipole and Monitor
The DVOR installation is commissioned either including nextfield monitor or with nextfield monitor as
supplementary part. First the installation is set to operation with the farfield dipole.
- Close all windows in the ADRACS user program.
- Select 'Adjustments' in the function key bar
Î
.
- Select windows for 'MON-1' and 'Miscellaneous'.
- Set 'Station type' to 'DVOR Farfield signal' and confirm.
The further setup procedure follows according section 4.3.
The farfield dipole is no longer used after a following change over to operation with nextfield dipoles:
a mobile field dipole remains connected until the end of the setup process, while the solidly installed
dipole can be connected permanently.
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...