6 CONTROLS
1234.5
BLOCKED CHARGE FILTER
FAULT
A
A
6.2J.5 WATER TEMPERATURE SCREEN ______________________________________
If the temperature increases to 108°C, the RED
LEDs (A) will flash at a rate of two flashes every
four seconds. The warning buzzer will sound at
the same rate and the “CLEAR BUGSCREEN”
warning replaces the centre icons and flashes.
Press the button under the check mark to
remove warning. The RED LED’s will flash and
the buzzer continues until the temperature has
decreased to under 108°C. When the
temperature reaches 110°C, the lift / lower
function is stopped and the power take off is
disengaged. The engine will shutdown at 115°C.
This occurrence will also be recorded to memory, the data recorded is:
Water Temperature limit reached, Date, Time, Engine Hours, time above 110°C. Maximum
temperature reached during the fault.
6.2J.6 BLOCKED CHARGE FILTER SCREEN___________________________________
This situation does not cause a fault until the hydraulic oil is
at operating temperature. If the charge filter is blocked the
icon will be shown, and the RED LED’s (A) will flash at a rate
of a 1s flash every 5 seconds. The buzzer will sound at the
same rate one second every 5 seconds.
The fault will also be recorded to memory, the data recorded
is:
Blocked Charge Filter, Date, Time, Engine Hours, length of
time engine continued to run after the fault occurred.
1234.5
CLEAR BUGSCREEN
A
A
Summary of Contents for Jacobsen Ransomes Parkway 3 Meteor LGNN344
Page 8: ...en 8 2 INTRODUCTION NOTES...
Page 33: ...en 33 SPECIFICATIONS 4 NOTES...
Page 87: ...en 87 MAINTENANCE LUBRICATION 8 NOTES...
Page 99: ...en 99 ADJUSTMENTS 9 NOTES...
Page 115: ...en 115 QUALITY OF CUT 12 NOTES...
Page 119: ......
Page 126: ...nl 8 2 INLEIDING OPMERKINGEN...
Page 151: ...nl 33 TECHNISCHE GEGEVENS 4 OPMERKINGEN...
Page 215: ...nl 97 AFSTELLING 9...
Page 231: ...nl 113 MAAIKWALITEIT 12...
Page 235: ......