6 Test procedures at engine
6.2 Checking generator
6.2 Checking generator
G1 Generator
Stator
2
Rotor
3
GX1
3-pole connection at
stator generator (yellow
wires)
1
►
Check all electrical contacts for corrosion and proper mechanical connection.
►
Make a continuity test with all relevant wires:
Continuity test with multimeter:
GX1-
Engine
ground
A
B
C
GX1-
A
d
d
–
B
d
–
C
–
d Continuity is required
Engine ground
– No continuity is permitted
►
If the wires are defective, replace the stator.
►
Perform a visual inspection of the rotor.
►
If mechanical defects are present, for example at the internal magnets, replace the rotor.