30
DHB MPE850 MAR Rev B | 408014 | 408090 | 408101 | 408246 |
5 Troubleshooting with trouble codes
5.2 Description of trouble codes
Trouble code
Displayed fault
Trouble code description
Possible consequences
Affected part/system
►
Possible consequences/remedy
P0615
Starter Relay Circuit
Open circuit at part or wire harness.
The engine does not crank.
Relay starter
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P0616
Starter Relay Circuit Low
Short circuit to ground at part or wire harness.
The engine does not crank.
Relay starter
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P0617
Starter Relay Circuit High
Short circuit to plus at part or wire harness.
The engine does not crank.
Relay starter
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P061B
Internal Control Module Torque Calculation
Performance
Throttle body
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P0625
Generator Field/F Terminal Circuit Low
Charging voltage too low.
Voltage regulator/Generator
►
Check wiring in the wire harness between
ECU 64pol-P2 and relay main. (See
chapter 7 Wiring diagram.)
►
Check the voltage regulator. (See chapter 6
Test procedures at engine.)
►
Check the generator. (See chapter 6 Test
procedures at engine.)
Summary of Contents for 408014