25
DHB MPE850 MAR Rev B | 408014 | 408090 | 408101 | 408246 |
5 Troubleshooting with trouble codes
5.2 Description of trouble codes
Trouble code
Displayed fault
Trouble code description
Possible consequences
Affected part/system
►
Possible consequences/remedy
P0238
Turbo/Super Charger Boost Sensor "A" Circuit
High
Short circuit to plus at part or wire harness.
Loss of power.
Sensor intercooler pressure
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P0244
Turbo/Super Charger Wastegate Solenoid "A"
Range/Performance
Open circuit at part or wire harness.
Loss of power.
Valve boost pressure control
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P0245
Turbo/Super Charger Wastegate Solenoid "A"
Low
Short circuit to ground at part or wire harness.
Loss of power.
Valve boost pressure control
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P0246
Turbo/Super Charger Wastegate Solenoid "A"
High
Short circuit to plus at part or wire harness.
Loss of power.
Valve boost pressure control
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
Summary of Contents for 408014