31
DHB MPE850 MAR Rev B | 408014 | 408090 | 408101 | 408246 |
5 Troubleshooting with trouble codes
5.2 Description of trouble codes
Trouble code
Displayed fault
Trouble code description
Possible consequences
Affected part/system
►
Possible consequences/remedy
P0626
Generator Field/F Terminal Circuit High
Charging voltage too high.
Voltage regulator/Generator
►
Check the voltage regulator. (See chapter 6
Test procedures at engine.)
►
Check the generator. (See chapter 6 Test
procedures at engine.)
P0638
Throttle Actuator Control Range/Performance
Bank 1
Throttle body
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P063A Auto Configuration Throttle Input - Adaptation
condition exceeded
Throttle body
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P063B
Auto Configuration Throttle Input - Limp home
adaptation is out of range
Throttle body
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
P063C Auto Configuration Throttle Input - Lower
mechanical stop adaptation is out of range
Throttle body
►
Check wiring in the wire harness to the
affected part. (See chapter 7 Wiring
diagram.)
►
Replace the affected part. (See the repair
manual.)
Summary of Contents for 408014
Page 2: ......