Tiger 320 Series Programming Code Sheet

Draft Copy. Code Version V3.08a

Texmate Inc. Tel. (760) 598 9899 • www.texmate.com

16

2 February, 2005   Prog. Code Sheet V3.08a (NZ101)

200

BAUD

PARITY

ADDRESS

TIME DELAY

1st DIGIT

2nd DIGIT

3rd DIGIT

CALIBRATION MODE [CAL] Continued

SUB-SETTINGS

RELATED CALIBRATION FUNCTIONS

201

BAUD

PARITY

ADDRESS

TIME DELAY

202

BAUD

PARITY

ADDRESS

TIME DELAY

203

BAUD

PARITY

ADDRESS

TIME DELAY

204

BAUD

PARITY

ADDRESS

TIME DELAY

Serial Output

Auto Zero Maintenance

210 AZ CAPTURE

AZ MOTION

AZ APERTURE

211 AZ CAPTURE

AZ MOTION

AZ APERTURE

212 AZ CAPTURE

AZ MOTION

AZ APERTURE

213 AZ CAPTURE

AZ MOTION

AZ APERTURE

214 AZ CAPTURE

AZ MOTION

AZ APERTURE

Averaging Samples & Averaging Window

220 AVERAGE SAMPLES

AVERAGE WINDOW

231

SCALE FACTOR

CUTOFF

240

MODE

251 ZERO

FULL SCALE

221 AVERAGE SAMPLES

AVERAGE WINDOW

222 AVERAGE SAMPLES

AVERAGE WINDOW

223 AVERAGE SAMPLES

AVERAGE WINDOW

224 AVERAGE SAMPLES

AVERAGE WINDOW

K Factor & Totalizer Cutoff

232

SCALE FACTOR

CUTOFF

32-point Linearization Tables

241

MODE

242

MODE

243

MODE

244

MODE

Scale Analog Output

252 ZERO

FULL SCALE

Summary of Contents for Tiger 320 Series

Page 1: ...on to all application function settings the configuration program also provides access to added features such as Code blanking Display text editing Configuration data copying Downloading macros to the...

Page 2: ...tware Version Number Press and hold the and buttons While holding both buttons press the Prog button then release all three buttons Programming Tip The Model and Software Code Version check ing proced...

Page 3: ...ideal for preventing settings such as calibra tion being changed by the operator Macros A macro is a set of commands that run auto matically when the controller is powered up Macros can be installed...

Page 4: ...s 8 9 and 10 shows the three digit configuration settings that are applied individually to each setpoint Display Brightness bri Allows you to adjust the display brightness in a range of 8 settings 0 b...

Page 5: ...time delay in milliseconds Except ASCII Mode which uses message terminators Use buttons to set AZ_A from 0 to 65535 counts P Auto zero motion Auto zero aperture window 0 1 Analog Output 1 2 Analog Out...

Page 6: ...options are only for use with meters that have more than one dis play With bargraph meters the PRIMARY display is the digital display and the SECONDARY display is the bargraph display Note 3 These fun...

Page 7: ...Register 2 2 Output Register 3 3 Output Register 4 4 Output Register 5 5 Output Register 6 6 Output Register 7 7 Smart Input Module Register 1 Code Setup See Note 7 THIRD DIGIT SECOND DIGIT CODE 2 No...

Page 8: ...ncy 99 999 Hz range from 0 001 Hz 1 Frequency 999 99 Hz range from 0 01 Hz 2 Frequency 99 999 kHz range from 1 Hz 1 s gate 3 Frequency 500 kHz range from 10 Hz 0 1 s gate 4 Period 9 9999 s 100 s resol...

Page 9: ...No Data Logging 1 Cyclic Buffer 2 Linear FIFO Buffer 3 Reset Buffer Number to 0 Note Setting Code 8 to 3XX resets the data log buffer to 0 Once reset Code 8 must be set back to the required data log...

Page 10: ...nts light up from the bottom of the bar and grow towards the top If bar nominal is set to the bar high setting this makes all seg ments from the displayed signal to the top of the bar light up As the...

Page 11: ...lay Latched and Manual Relay Reset 4 Relay Latched Off 5 Hysteresis Deviation PID Mode includes SP Tracking 6 Timer Modes OFF Normal Delay Repeat ON Pulse ON 1 Shot ON Repeat OFF Pulse OFF 1 Shot OFF...

Page 12: ...6553 5 65 535 secs DOB 0 1 0 001 to 6553 5 65 535 secs On_t 0 1 0 001 to 6553 5 65 535 secs Off time oFF_t 0 1 0 001 to 6553 5 65 535 secs Off time oFF_t 0 1 0 001 to 6553 5 65 535 secs Minimum off t...

Page 13: ...ramming Tip This mode can not be accessed if SPC_1 or SPC_2 is in the PID mode Select reset trigger from 1 of 4 relay operating edges Reset Trigger Select register to be reset Reset Destination Regist...

Page 14: ...illed Cases Totalizer 1 Flow Channel 2 Bottles SP5 2 00 Hi Setpoint SP6 2 00 Hi Setpoint SP4 12 Hi Setpoint SP3 12 Hi Setpoint S O U R C E R E S E T R E S E T I N C R E M E N T I N C R E M E N T S O U...

Page 15: ...022 SPAN 032 ZERO SPAN 042 CHANNEL 052 CHANNEL 012 INPUT INPUT INPUT CH2 023 SPAN 033 ZERO SPAN 043 CHANNEL 053 CHANNEL 013 INPUT INPUT INPUT CH3 024 SPAN 034 ZERO SPAN 044 CHANNEL 054 CHANNEL 014 IN...

Page 16: ...Y Serial Output Auto Zero Maintenance 210 AZ CAPTURE AZ MOTION AZ APERTURE 211 AZ CAPTURE AZ MOTION AZ APERTURE 212 AZ CAPTURE AZ MOTION AZ APERTURE 213 AZ CAPTURE AZ MOTION AZ APERTURE 214 AZ CAPTURE...

Page 17: ...CODE 2 PRESCALER 1st DIGIT 2nd DIGIT 3rd DIGIT CODE 3 1st DIGIT 2nd DIGIT 3rd DIGIT CODE 4 PRESCALER 1st DIGIT 2nd DIGIT 3rd DIGIT CODE 5 SMART INPUT MODULE SETTINGS 1st DIGIT 2nd DIGIT 3rd DIGIT COD...

Page 18: ...INT DER ARW MCT SP TRACKING SPAN PB INT DER ARW MCT SP TRACKING SPAN PB INT DER ARW MCT SP TRACKING SPAN PB INT DER ARW MCT SP TRACKING TIMER MODE SETTINGS SPC_1 _ _ 6 SPC_2 SPC_3 SPC_4 SPC_5 SPC_6 _...

Page 19: ...reset destination for the above func tions are shown in the table opposite This table shows in seven columns the functions where these registers can be used Where a register is more likely to be used...

Page 20: ...tion Select K Type Thermocouple for Initial Calibration S S T T E E P P 2 2 Enter the Calibration mode CAL set to 121 and press the button twice to carry out the thermocouple initial calibration proce...