81
4.
The Phase parameter will become highlighted in the
Waveform Display area.
5.
Use the arrow keys and scroll
wheel or number pad to enter the
phase.
0
/
3
2
1
4
7
8
5
9
6
6.
Press F2 (Degreee) to select the
phase unit.
Degree
F2
Range
Phase
-360
˚~+360˚
Default
0˚
Note
When using sine, square, triangle or ramp waveforms,
0˚
is the point where the waveforms are at zero volts.
0˚ is the starting point of a waveform. For sine, square or
Triangle, Ramp
waveforms, 0˚ is at 0 volts (assuming
there is no DC offset).
Burst Phase is used for both N cycle and Gated burst
modes. In gated burst mode, when the Trigger INPUT
signal goes low the output is stopped after the current
waveform is finished. The voltage output level will remain
equal to the voltage at the starting burst phase.
Summary of Contents for FGX-2220
Page 1: ...B71 0406 01 INSTRUCTION MANUAL ARBITRARY FUNCTION GENERATOR FGX 2220...
Page 98: ...85...
Page 137: ...124...
Page 227: ...214 9 2 External Dimensions Figure...