39
TMS570LS0714
www.ti.com
SPNS226E – JUNE 2013 – REVISED NOVEMBER 2016
Submit Documentation Feedback
Product Folder Links:
TMS570LS0714
Specifications
Copyright © 2013–2016, Texas Instruments Incorporated
(1)
The typical value is the average current for the nominal process corner and junction temperature of 25°C.
(2)
The maximum I
CC,
value can be derated
•
linearly with voltage
•
by 0.85 mA/MHz for lower operating frequency when f
HCLK
= 2 * f
VCLK
•
for lower junction temperature by the equation below where T
JK
is the junction temperature in Kelvin and the result is in milliamperes.
126 - 0.005 e
0.024 T
JK
(3)
The maximum I
CC,
value can be derated
•
linearly with voltage
•
by 0.85 mA/MHz for lower operating frequency
•
for lower junction temperature by the equation below where T
JK
is the junction temperature in Kelvin and the result is in milliamperes.
126 - 0.005 e
0.024 T
JK
(4)
LBIST and PBIST currents are for a short duration, typically less than 10 ms. They are usually ignored for thermal calculations for the
device and the voltage regulator.
5.6
Power Consumption Over Recommended Operating Conditions
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
I
CC
V
CC
digital supply current (operating mode)
f
VCLK
= f
HCLK
/2; Flash in pipelined mode;
V
CCmax
f
HCLK
= 100 MHz
130
(1)
270
(2)
mA
f
HCLK
= 160 MHz
160
(1)
300
(2)
V
CC
digital supply current (LBIST/PBIST mode)
LBIST/PBIST clock
frequency = 50 MHz
150
(1)
290
(3) (4)
mA
LBIST/PBIST clock
frequency = 80 MHz
215
(1)
360
(3) (4)
LBIST/PBIST clock
frequency = 90 MHz
240
(1)
390
(3) (4)
I
CCIO
V
CCIO
digital supply current (operating mode)
No DC load, V
CCmax
15
mA
I
CCAD
V
CCAD
supply current (operating mode)
Single ADC
operational,
V
CCADmax
15
mA
Both ADCs
operational,
V
CCADmax
30
I
CCREFHI
AD
REFHI
supply current (operating mode)
Single ADC
operational,
AD
REFHImax
3
mA
Both ADCs
operational,
AD
REFHImax
6
I
CCP
V
CCP
supply current
Read from 1 bank
and program
another bank,
V
CCPmax
55